EUVIMEDEUVIMED entdecken
Crossref

Motion corrected 3D whole‐heart SAVA T 1 mapping at 0.55 T

Rafael I De la Sotta iD, Michael G Crabb iD, Karl P Kunze, René M Botnar, Claudia Prieto

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Rafael I De la Sotta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Heart, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: EPSRC, Wellcome EPSRC Centre for Medical Engineering, Millennium Institute for Intelligent Healthcare Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To propose a novel highly efficient isotropic‐resolution 3D whole‐heart saturation‐recovery and variable‐flip‐angle (SAVA) T 1 mapping sequence at 0.55 T, incorporating image navigator (iNAV)‐based non‐rigid motion correction and dictionary matching.

Methods

The proposed iNAV‐based isotropic‐resolution 3D whole‐heart SAVA T 1 mapping sequence at 0.55 T acquires three gradient echo T 1 ‐weighted volumes sequentially: an equilibrium contrast with 4° flip angle, and two saturation recovery T 1 ‐weighted contrasts with 10° flip angles and different saturation delays. Sequence parameters were optimized for the lower field strength by simulations and phantom experiments. Two‐dimensional iNAVs are acquired at each heartbeat to enable respiratory motion estimation and correction and 100% respiratory scan efficiency. The T 1 mapping is computed by dictionary matching, using subject‐specific dictionaries based on Bloch equations simulations. Non‐rigid motion correction is implemented based on respiratory bins reconstructed by iterative‐SENSE and subsequent patch‐based low‐rank denoising, for each contrast separately. The proposed approach was evaluated in a standardized T 1 phantom and 10 healthy subjects, in comparison to spin‐echo reference and 2D MOLLI, respectively.

Results

Excellent agreement is observed between iNAV‐based SAVA T 1 mapping at 0.55 T and spin echo reference in phantom, with a for all phantom vials. Good image quality was obtained in vivo for the contrast images and corresponding T 1 maps in a scan time of 6:30 min ±40 s. Average and SD of myocardial T 1 values across subjects and segments was 706 ± 41 ms, which is comparable to acquired 2D MOLLI values of 681 ± 26 ms, and previously reported 2D MOLLI values of 701 ± 24 ms. Coefficient of variation values (12%) are higher than those previously reported for diaphragmatic navigator‐based non‐isotropic SAVA T 1 mapping at 3 T (7.4%).

Conclusion

The proposed iNAV‐based SAVA approach achieves free‐breathing motion‐corrected 3D whole‐heart T 1 mapping at 0.55 T in approximately 7 min scan time for an isotropic resolution of 2 mm. In vivo experiments showed that the proposed sequence achieves good map quality, with comparable T 1 values and spatial variability compared to 2D MOLLI T 1 mapping. Further evaluation is warranted in patients with cardiovascular disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalHeartMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansPhantoms, ImagingAlgorithmsMotionAdultMaleFemaleComputer SimulationRespiration

Stichwörter der Autor:innen

cardiac MRIfree‐breathinglow‐fieldmyocardial T1 mappingwhole‐heart

Autor:innen und Institutionen

  • Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • MR Research Collaborations, Siemens Healthcare, Camberley, UK.
  • School of Engineering, Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
  • Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.

ORCID-Profile: Rafael I De la Sotta, Michael G Crabb

Förderung

  • EPSRC
  • Wellcome EPSRC Centre for Medical Engineering
  • Millennium Institute for Intelligent Healthcare Engineering
  • Fondequip Mayor
  • King's BHF Centre for Award Excellence
  • ANID Fondecyt
  • BHF programme
  • Engineering and Physical Sciences Research Council

Zitieren

APA

De la Sotta, R. I., Crabb, M. G., Kunze, K. P., Botnar, R. M., & Prieto, C. (2026). Motion corrected 3D whole‐heart SAVA T 1 mapping at 0.55 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70038

Vancouver

De la Sotta RI, Crabb MG, Kunze KP, Botnar RM, Prieto C. Motion corrected 3D whole‐heart SAVA T 1 mapping at 0.55 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70038

BibTeX
@article{DelaSotta2026,
  author = {De la Sotta, Rafael I and Crabb, Michael G and Kunze, Karl P and Botnar, René M and Prieto, Claudia},
  title = {Motion corrected 3D whole‐heart SAVA T 1 mapping at 0.55 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70038}
}