Abdominal MR Multitasking for radiotherapy treatment planning: A motion‐resolved and multicontrast 3D imaging approach
Magnetic Resonance in Medicine · 2025-01 · 93 (1) · 108-120
DOI: 10.1002/mrm.30256 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 22.08.2024. Verfasst von Junzhou Chen und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Southern California, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Radiotherapy Planning, Computer-Assisted, Magnetic Resonance Imaging, Abdomen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
Purpose
Radiotherapy treatment planning (RTP) using MR has been used increasingly for the abdominal site. Multiple contrast weightings and motion‐resolved imaging are desired for accurate delineation of the target and various organs‐at‐risk and patient‐tailored planning. Current MR protocols achieve these through multiple scans with distinct contrast and variable respiratory motion management strategies and acquisition parameters, leading to a complex and inaccurate planning process. This study presents a standalone MR Multitasking (MT)–based technique to produce volumetric, motion‐resolved, multicontrast images for abdominal radiotherapy treatment planning.
Methods
The MT technique resolves motion and provides a wide range of contrast weightings by repeating a magnetization‐prepared (saturation recovery and T 2 preparations) spoiled gradient‐echo readout series and adopting the MT image reconstruction framework. The performance of the technique was assessed through digital phantom simulations and in vivo studies of both healthy volunteers and patients with liver tumors.
Results
In the digital phantom study, the MT technique presented structural details and motion in excellent agreement with the digital ground truth. The in vivo studies showed that the motion range was highly correlated (R 2 = 0.82) between MT and 2D cine imaging. MT allowed for a flexible contrast‐weighting selection for better visualization. Initial clinical testing with interobserver analysis demonstrated acceptable target delineation quality (Dice coefficient = 0.85 ± 0.05, Hausdorff distance = 3.3 ± 0.72 mm).
Conclusion
The developed MT‐based, abdomen‐dedicated technique is capable of providing motion‐resolved, multicontrast volumetric images in a single scan, which may facilitate abdominal radiotherapy treatment planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Southern California, Los Angeles, California, USA.
- Department of Radiation Oncology, University of Southern California, Los Angeles, California, USA.
- Department of Bioengineering, University of California, Los Angeles, California, USA.
- Biomedical Imaging Research Institute, Cedars Sinai Medical Center, Los Angeles, California, USA.
- Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania, USA.
- Department of Radiation Oncology, University of California, San Francisco, California, USA.
ORCID-Profile: Junzhou Chen, Anthony G Christodoulou, Pei Han, Sophia Cui, Zhaoyang Fan
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Chen, J., Christodoulou, A. G., Han, P., Xiao, J., Han, F., Hu, Z., Wang, N., Han, H., Ling, D. C., Chang, E. L., Feng, M., Scholey, J. E., Cui, S., Li, D., Yang, W., & Fan, Z. (2025). Abdominal MR Multitasking for radiotherapy treatment planning: A motion‐resolved and multicontrast 3D imaging approach. Magnetic Resonance in Medicine, 93(1), 108-120. https://doi.org/10.1002/mrm.30256
Vancouver
Chen J, Christodoulou AG, Han P, Xiao J, Han F, Hu Z, et al. Abdominal MR Multitasking for radiotherapy treatment planning: A motion‐resolved and multicontrast 3D imaging approach. Magnetic Resonance in Medicine. 2025;93(1):108-120. doi:10.1002/mrm.30256
BibTeX
@article{Chen2025,
author = {Chen, Junzhou and Christodoulou, Anthony G and Han, Pei and Xiao, Jiayu and Han, Fei and Hu, Zhehao and Wang, Nan and Han, Hui and Ling, Diane C and Chang, Eric L and Feng, Mary and Scholey, Jessica E and Cui, Sophia and Li, Debiao and Yang, Wensha and Fan, Zhaoyang},
title = {Abdominal MR Multitasking for radiotherapy treatment planning: A motion‐resolved and multicontrast 3D imaging approach},
journal = {Magnetic Resonance in Medicine},
year = {2025},
volume = {93},
number = {1},
pages = {108--120},
doi = {10.1002/mrm.30256}
}
EUVIMED