Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Donovan P Tripp und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Liver, Imaging, Three-Dimensional, Adipose Tissue, Magnetic Resonance Imaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute for Health Research (NIHR) MedTech Co-operative, Technical University of Munich-Institute for Advanced Study, EPSRC Centre for Doctoral Training in Smart Medical Imaging.
Abstract (Originalsprache)
Purpose
To develop a framework for simultaneous three‐dimensional (3D) mapping of , , and fat signal fraction in the liver at 0.55 T.
Methods
The proposed sequence acquires four interleaved 3D volumes with a two‐echo Dixon readout. and are encoded into each volume via preparation modules, and dictionary matching allows simultaneous estimation of , , and for water and fat separately. 2D image navigators permit respiratory binning, and motion fields from nonrigid registration between bins are used in a nonrigid respiratory‐motion‐corrected reconstruction, enabling 100% scan efficiency from a free‐breathing acquisition. The integrated nature of the framework ensures the resulting maps are always co‐registered. Results , , and fat‐signal‐fraction measurements in phantoms correlated strongly (adjusted ) with reference measurements. Mean liver tissue parameter values in 10 healthy volunteers were , , and for , , and fat signal fraction, giving biases of , , and percentage points, respectively, when compared to conventional methods.
Conclusion
A novel sequence for comprehensive characterization of liver tissue at 0.55 T was developed. The sequence provides co‐registered 3D , , and fat‐signal‐fraction maps with full coverage of the liver, from a single nine‐and‐a‐half‐minute free‐breathing scan. Further development is needed to achieve accurate proton‐density fat fraction (PDFF) estimation in vivo.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
- MR Research Collaborations, Siemens Healthcare Limited, Camberley, UK.
- School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
- Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
ORCID-Profile: Donovan P Tripp, Karl P Kunze, Michael G Crabb, Claudia Prieto, Radhouene Neji, René M Botnar
Förderung
- National Institute for Health Research (NIHR) MedTech Co-operative
- Technical University of Munich-Institute for Advanced Study
- EPSRC Centre for Doctoral Training in Smart Medical Imaging
- Siemens Healthineers
- Wellcome EPSRC Centre for Medical Engineering
- Engineering and Physical Sciences Research Council
- Fondo Nacional de Desarrollo Científico y Tecnológico
- ANID BASAL Centre of Interventional Medicine for Precision and Advanced Cellular Therapy
Zitieren
APA
Tripp, D. P., Kunze, K. P., Crabb, M. G., Prieto, C., Neji, R., & Botnar, R. M. (2024). Simultaneous 3D T1$$ {\mathrm{T}}_1 $$, T2$$ {\mathrm{T}}_2 $$, and fat‐signal‐fraction mapping with respiratory‐motion correction for comprehensive liver tissue characterization at 0.55 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30236
Vancouver
Tripp DP, Kunze KP, Crabb MG, Prieto C, Neji R, Botnar RM. Simultaneous 3D T1$$ {\mathrm{T}}_1 $$, T2$$ {\mathrm{T}}_2 $$, and fat‐signal‐fraction mapping with respiratory‐motion correction for comprehensive liver tissue characterization at 0.55 T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30236
BibTeX
@article{Tripp2024,
author = {Tripp, Donovan P and Kunze, Karl P and Crabb, Michael G and Prieto, Claudia and Neji, Radhouene and Botnar, René M},
title = {Simultaneous 3D T1$$ \mathrmT_1 $$, T2$$ \mathrmT_2 $$, and fat‐signal‐fraction mapping with respiratory‐motion correction for comprehensive liver tissue characterization at 0.55 T},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30236}
}
EUVIMED