EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prospective motion correction for R2* and susceptibility mapping using spherical navigators

Miriam Hewlett iD, Omer Oran iD, Junmin Liu iD, Maria Drangova iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Miriam Hewlett und 3 weiteren Autor:innen. Beteiligte Einrichtung: Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CIHR, Natural Sciences and Engineering Research Council of Canada, Canadian Institutes of Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To perform prospective motion correction (PMC) for improved and susceptibility mapping using a purely navigator‐based approach.

Methods

Spherical navigators (SNAVs) were combined with an additional FID readout for simultaneous measurement of motion and zeroth‐order field shifts. The resulting FIDSNAVs were interleaved for PMC of a multi‐echo gradient echo sequence with retrospective correction. Experiments were performed on a 3T scanner with a 32‐channel head coil. Performance was assessed in five volunteers with motion prompts derived from real unintentional motion trajectories.

Results

At short TEs, PMC alone was sufficient to achieve good image quality; at longer TEs, retrospective correction was often just as important for artifact reduction as motion correction. Both PMC and retrospective correction reduced error in and susceptibility maps for all participants. Residual artifacts were observed in the most severe motion case.

Conclusion

Combining SNAVs with an additional FID readout enables simultaneous motion and field correction with no additional hardware requirements, improving the fidelity of quantitative mapping in the presence of motion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainImage Processing, Computer-AssistedHumansArtifactsMotionAlgorithmsAdultMaleFemale

Stichwörter der Autor:innen

R 2 * $$ {R}_2^{\ast } $$ mappingbrainnavigatorsprospective motion correctionsusceptibility mapping

Autor:innen und Institutionen

  • Robarts Research Institute, The University of Western Ontario, London, Ontario, Canada.
  • Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada.
  • Siemens Healthcare Limited, Oakville, Ontario, Canada.

ORCID-Profile: Miriam Hewlett, Omer Oran, Junmin Liu, Maria Drangova

Förderung

  • CIHR
  • Natural Sciences and Engineering Research Council of Canada
  • Canadian Institutes of Health Research

Zitieren

APA

Hewlett, M., Oran, O., Liu, J., & Drangova, M. (2025). Prospective motion correction for R2* and susceptibility mapping using spherical navigators. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30385

Vancouver

Hewlett M, Oran O, Liu J, Drangova M. Prospective motion correction for R2* and susceptibility mapping using spherical navigators. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30385

BibTeX
@article{Hewlett2025,
  author = {Hewlett, Miriam and Oran, Omer and Liu, Junmin and Drangova, Maria},
  title = {Prospective motion correction for R2* and susceptibility mapping using spherical navigators},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30385}
}
Kostenlos starten →