Self‐Navigated, Retrospective, Data‐Consistent Motion Correction for MPnRAGE
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70126 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von John Podczerwinski und 4 weiteren Autor:innen. Beteiligte Einrichtung: Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS, NIMH NIH HHS, NIDCD NIH HHS.
Abstract (Originalsprache)
Purpose
To extend and automate a data‐consistent, self‐navigated motion‐correction method for 3D radial T1‐weighted imaging.
Methods
This method incorporated rigid‐body motion effects into the forward model, solving for parameters that maximize consistency with the data. The method was tested on five datasets with a range of motion types and severities. A separate collection of datasets was used to study the effect that the method has on the test‐retest reliability of cortical thickness estimates.
Results
Image quality was improved across a wide range of distinct motion types, including some cases that would have been unusable if left uncorrected. The error‐based weighting scheme and the increased timing resolution afforded by the proposed method were especially useful in cases of extreme and rapid motions. Moreover, the method improved test‐retest reliability of cortical thickness measures in pediatric subjects, decreasing the average coefficient of variation from in uncorrected images (with freesurfer failing on one subject) down to for images corrected at timing resolution and when corrected at faster temporal rates.
Conclusion
This method was found to be effective when used on T1‐weighted radial data, both qualitatively and quantitatively. The fine‐scale timing resolution and error‐based weighting afforded by this technique will likely provide only a small benefit, unless one is investigating motion‐prone populations or is searching for a very small effect size.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Waisman Center, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Psychiatry, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Kinesiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Department of Psychology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: John Podczerwinski, Andrew L Alexander, Brittany G Travers, James J Li, Steven R Kecskemeti
Förderung
- NICHD NIH HHS
- NIMH NIH HHS
- NIDCD NIH HHS
- ORIP NIH HHS
- NIH HHS
- NIA NIH HHS
- Eunice Kennedy Shriver National Institute of Child Health and Human Development
- Office of Research Infrastructure Programs
Zitieren
APA
Podczerwinski, J., Alexander, A. L., Travers, B. G., Li, J. J., & Kecskemeti, S. R. (2026). Self‐Navigated, Retrospective, Data‐Consistent Motion Correction for MPnRAGE. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70126
Vancouver
Podczerwinski J, Alexander AL, Travers BG, Li JJ, Kecskemeti SR. Self‐Navigated, Retrospective, Data‐Consistent Motion Correction for MPnRAGE. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70126
BibTeX
@article{Podczerwinski2026,
author = {Podczerwinski, John and Alexander, Andrew L and Travers, Brittany G and Li, James J and Kecskemeti, Steven R},
title = {Self‐Navigated, Retrospective, Data‐Consistent Motion Correction for MPnRAGE},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70126}
}