EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preparation‐based B 1+ mapping in the heart using Bloch–Siegert shifts

Paulina Šiurytė iD, Joao Tourais iD, Yi Zhang iD, Chiara Coletti iD, Christal van de Steeg-Henzen, Stefano Mandija iD, Qian Tao, Markus Henningsson iD, Sebastian Weingärtner iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30232 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Paulina Šiurytė und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands. Hauptthemen laut MEDLINE: Phantoms, Imaging, Heart, Algorithms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Hartstichting, Nederlandse Organisatie voor Wetenschappelijk Onderzoek, 4TU Precision Medicine program supported by High Tech for a Sustainable Future.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and evaluate a robust cardiac mapping sequence at 3 T, using Bloch–Siegert shift (BSS)‐based preparations.

Methods

A longitudinal magnetization preparation module was designed to encode . After magnetization tip‐down, off‐resonant Fermi pulses, placed symmetrically around two refocusing pulses, induced BSS, followed by tipping back of the magnetization. Bloch simulations were used to optimize refocusing pulse parameters and to assess the mapping sensitivity. Relaxation‐induced error was simulated for various / times. The effective mapping range was determined in phantom experiments, and maps were compared to the conventional BSS method and subadiabatic hyperbolic‐secant 8 (HS8) pulse‐sensitized method. Cardiac maps were acquired in healthy subjects, and evaluated for repeatability and imaging plane intersection consistency. The technique was modified for three‐dimensional (3D) acquisition of the whole heart in a single breath‐hold, and compared to two‐dimensional (2D) acquisition.

Results

Simulations indicate that the proposed preparation can be tailored to achieve high mapping sensitivity across various ranges, with maximum sensitivity at the upper range. /‐induced bias did not exceed 5.2. Experimentally reproduced sensitization closely matched simulations for (mean difference 0.0310.022, compared to 0.0180.025 in the HS8‐sensitized method), and showed 20‐fold reduction in the standard deviation of repeated scans, compared with conventional BSS mapping, and an equivalent 2‐fold reduction compared with HS8‐sensitization. Robust cardiac map quality was obtained, with an average test‐retest variability of 0.0270.043 relative to normalized magnitude, and plane intersection bias of 0.0520.031. 3D acquisitions showed good agreement with 2D scans (mean absolute deviation 0.0550.061).

Conclusion

BSS‐based preparations enable robust and tailorable 2D/3D cardiac mapping at 3 T in a single breath‐hold.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingHeartAlgorithmsMagnetic Resonance ImagingHumansComputer SimulationImage Processing, Computer-AssistedReproducibility of ResultsMaleAdultImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

B 1 + $$ {}_1^{+} $$ mappingBloch–Siegert shiftcardiac imagingpreparation‐based

Autor:innen und Institutionen

  • Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
  • HollandPTC, Delft, The Netherlands.
  • Department of Radiotherapy, Division of Imaging & Oncology, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.

ORCID-Profile: Paulina Šiurytė, Joao Tourais, Yi Zhang, Chiara Coletti, Stefano Mandija, Markus Henningsson, Sebastian Weingärtner

Förderung

  • Nederlandse Hartstichting
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek
  • 4TU Precision Medicine program supported by High Tech for a Sustainable Future
  • European Research Council

Zitieren

APA

Šiurytė, P., Tourais, J., Zhang, Y., Coletti, C., van de Steeg-Henzen, C., Mandija, S., Tao, Q., Henningsson, M., & Weingärtner, S. (2024). Preparation‐based B 1+ mapping in the heart using Bloch–Siegert shifts. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30232

Vancouver

Šiurytė P, Tourais J, Zhang Y, Coletti C, van de Steeg-Henzen C, Mandija S, et al. Preparation‐based B 1+ mapping in the heart using Bloch–Siegert shifts. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30232

BibTeX
@article{iuryt2024,
  author = {Šiurytė, Paulina and Tourais, Joao and Zhang, Yi and Coletti, Chiara and van de Steeg-Henzen, Christal and Mandija, Stefano and Tao, Qian and Henningsson, Markus and Weingärtner, Sebastian},
  title = {Preparation‐based B 1+ mapping in the heart using Bloch–Siegert shifts},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30232}
}
Kostenlos starten →