EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accelerated free‐breathing liver fat and R2* quantification using multi‐echo stack‐of‐radial MRI with motion‐resolved multidimensional regularized reconstruction: Initial retrospective evaluation

Xiaodong Zhong iD, Marcel D Nickel, Stephan A R Kannengiesser, Brian M Dale, Fei Han, Chang Gao, Shu-Fu Shih iD, Qing Dai, Omar Curiel, Tsu-Chin Tsao, Holden H Wu iD, Vibhas Deshpande

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30117 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Xiaodong Zhong und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Liver, Phantoms, Imaging, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Medical Solutions USA, Inc, the Department of Radiological Sciences at the University of California Los Angeles, Siemens Medical Solutions USA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve image quality, mitigate quantification biases and variations for free‐breathing liver proton density fat fraction (PDFF) and quantification accelerated by radial k‐space undersampling.

Methods

A free‐breathing multi‐echo stack‐of‐radial MRI method was developed with compressed sensing with multidimensional regularization. It was validated in motion phantoms with reference acquisitions without motion and in 11 subjects (6 patients with nonalcoholic fatty liver disease) with reference breath‐hold Cartesian acquisitions. Images, PDFF, and maps were reconstructed using different radial view k‐space sampling factors and reconstruction settings. Results were compared with reference‐standard results using Bland–Altman analysis. Using linear mixed‐effects model fitting ( p < 0.05 considered significant), mean and SD were evaluated for biases and variations of PDFF and , respectively, and coefficient of variation on the first echo image was evaluated as a surrogate for image quality.

Results

Using the empirically determined optimal sampling factor of 0.25 in the accelerated in vivo protocols, mean differences and limits of agreement for the proposed method were [−0.5; −33.6, 32.7] s −1 for and [−1.0%; −5.8%, 3.8%] for PDFF, close to those of a previous self‐gating method using fully sampled radial views: [−0.1; −27.1, 27.0] s −1 for and [−0.4%; −4.5%, 3.7%] for PDFF. The proposed method had significantly lower coefficient of variation than other methods ( p < 0.001). Effective acquisition time of 64 s or 59 s was achieved, compared with 171 s or 153 s for two baseline protocols with different radial views corresponding to sampling factor of 1.0.

Conclusion

This proposed method may allow accelerated free‐breathing liver PDFF and mapping with reduced biases and variations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverPhantoms, ImagingMagnetic Resonance ImagingImage Processing, Computer-AssistedHumansRetrospective StudiesFemaleMaleMiddle AgedRespirationAlgorithmsAdultReproducibility of ResultsNon-alcoholic Fatty Liver DiseaseMotionAdipose TissueImage Interpretation, Computer-AssistedAged

Stichwörter der Autor:innen

XD‐GRASPmotion‐resolvedproton density fat fraction R 2 * $$ {\mathrm{R}}_2^{\ast } $$radial MRIregularizationself‐gating

Autor:innen und Institutionen

  • Department of Radiological Sciences, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.
  • Physics and Biology in Medicine Interdepartmental Program, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California, USA.
  • Department of Bioengineering, Samueli School of Engineering, University of California Los Angeles, Los Angeles, California, USA.
  • MR Application Predevelopment, Siemens Healthineers AG, Erlangen, Germany.
  • MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Cary, North Carolina, USA.
  • MR R&D Collaborations, Siemens Medical Solutions USA, Inc, Los Angeles, California, USA.

ORCID-Profile: Xiaodong Zhong, Shu-Fu Shih, Holden H Wu

Förderung

  • Siemens Medical Solutions USA, Inc
  • the Department of Radiological Sciences at the University of California Los Angeles
  • Siemens Medical Solutions USA

Zitieren

APA

Zhong, X., Nickel, M. D., Kannengiesser, S. A. R., Dale, B. M., Han, F., Gao, C., Shih, S. F., Dai, Q., Curiel, O., Tsao, T. C., Wu, H. H., & Deshpande, V. (2024). Accelerated free‐breathing liver fat and R2* quantification using multi‐echo stack‐of‐radial MRI with motion‐resolved multidimensional regularized reconstruction: Initial retrospective evaluation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30117

Vancouver

Zhong X, Nickel MD, Kannengiesser SAR, Dale BM, Han F, Gao C, et al. Accelerated free‐breathing liver fat and R2* quantification using multi‐echo stack‐of‐radial MRI with motion‐resolved multidimensional regularized reconstruction: Initial retrospective evaluation. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30117

BibTeX
@article{Zhong2024,
  author = {Zhong, Xiaodong and Nickel, Marcel D and Kannengiesser, Stephan A R and Dale, Brian M and Han, Fei and Gao, Chang and Shih, Shu-Fu and Dai, Qing and Curiel, Omar and Tsao, Tsu-Chin and Wu, Holden H and Deshpande, Vibhas},
  title = {Accelerated free‐breathing liver fat and R2* quantification using multi‐echo stack‐of‐radial MRI with motion‐resolved multidimensional regularized reconstruction: Initial retrospective evaluation},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30117}
}
Kostenlos starten →