Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30213 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Nienke P M Wassenaar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Algorithms, Contrast Media. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: KWF Kankerbestrijding.
Abstract (Originalsprache)
Purpose
For reliable DCE MRI parameter estimation, k‐space undersampling is essential to meet resolution, coverage, and signal‐to‐noise requirements. Pseudo‐spiral (PS) sampling achieves this by sampling k‐space on a Cartesian grid following a spiral trajectory. The goal was to optimize PS k‐space sampling patterns for abdomin al DCE MRI.
Methods
The optimal PS k‐space sampling pattern was determined using an anthropomorphic digital phantom. Contrast agent inflow was simulated in the liver, spleen, pancreas, and pancreatic ductal adenocarcinoma (PDAC). A total of 704 variable sampling and reconstruction approaches were created using three algorithms using different parametrizations to control sampling density, halfscan and compressed sensing regularization. The sampling patterns were evaluated based on image quality scores and the accuracy and precision of the DCE pharmacokinetic parameters. The best and worst strategies were assessed in vivo in five healthy volunteers without contrast agent administration. The best strategy was tested in a DCE scan of a PDAC patient.
Results
The best PS reconstruction was found to be PS‐diffuse based, with quadratic distribution of readouts on a spiral, without random shuffling, halfscan factor of 0.8, and total variation regularization of 0.05 in the spatial and temporal domains. The best scoring strategy showed sharper images with less prominent artifacts in healthy volunteers compared to the worst strategy. Our suggested DCE sampling strategy also showed high quality DCE images in the PDAC patient.
Conclusion
Using an anthropomorphic digital phantom, we identified an optimal PS sampling strategy for abdominal DCE MRI, and demonstrated feasibility in a PDAC patient.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
- Imaging and Biomarkers, Cancer Center Amsterdam, Amsterdam, The Netherlands.
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.
- Computational Imaging Group for MRI diagnostics and Therapy, Centre for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Medical Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands.
ORCID-Profile: Nienke P M Wassenaar, Eric M Schrauben
Förderung
- KWF Kankerbestrijding
Zitieren
APA
Wassenaar, N. P. M., Gurney-Champion, O. J., van Schelt, A. S., Bruijnen, T., van Laarhoven, H. W. M., Stoker, J., Nederveen, A. J., Runge, J. H., & Schrauben, E. M. (2024). Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30213
Vancouver
Wassenaar NPM, Gurney-Champion OJ, van Schelt AS, Bruijnen T, van Laarhoven HWM, Stoker J, et al. Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30213
BibTeX
@article{Wassenaar2024,
author = {Wassenaar, Nienke P M and Gurney-Champion, Oliver J and van Schelt, Anne-Sophie and Bruijnen, Tom and van Laarhoven, Hanneke W M and Stoker, Jaap and Nederveen, Aart J and Runge, Jurgen H and Schrauben, Eric M},
title = {Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30213}
}
EUVIMED