EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom

Nienke P M Wassenaar iD, Oliver J Gurney-Champion, Anne-Sophie van Schelt, Tom Bruijnen, Hanneke W M van Laarhoven, Jaap Stoker, Aart J Nederveen, Jurgen H Runge, Eric M Schrauben iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30213 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Nienke P M Wassenaar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Phantoms, Imaging, Magnetic Resonance Imaging, Algorithms, Contrast Media. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: KWF Kankerbestrijding.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

For reliable DCE MRI parameter estimation, k‐space undersampling is essential to meet resolution, coverage, and signal‐to‐noise requirements. Pseudo‐spiral (PS) sampling achieves this by sampling k‐space on a Cartesian grid following a spiral trajectory. The goal was to optimize PS k‐space sampling patterns for abdomin al DCE MRI.

Methods

The optimal PS k‐space sampling pattern was determined using an anthropomorphic digital phantom. Contrast agent inflow was simulated in the liver, spleen, pancreas, and pancreatic ductal adenocarcinoma (PDAC). A total of 704 variable sampling and reconstruction approaches were created using three algorithms using different parametrizations to control sampling density, halfscan and compressed sensing regularization. The sampling patterns were evaluated based on image quality scores and the accuracy and precision of the DCE pharmacokinetic parameters. The best and worst strategies were assessed in vivo in five healthy volunteers without contrast agent administration. The best strategy was tested in a DCE scan of a PDAC patient.

Results

The best PS reconstruction was found to be PS‐diffuse based, with quadratic distribution of readouts on a spiral, without random shuffling, halfscan factor of 0.8, and total variation regularization of 0.05 in the spatial and temporal domains. The best scoring strategy showed sharper images with less prominent artifacts in healthy volunteers compared to the worst strategy. Our suggested DCE sampling strategy also showed high quality DCE images in the PDAC patient.

Conclusion

Using an anthropomorphic digital phantom, we identified an optimal PS sampling strategy for abdominal DCE MRI, and demonstrated feasibility in a PDAC patient.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingMagnetic Resonance ImagingAlgorithmsContrast MediaAbdomenImage Processing, Computer-AssistedPancreatic NeoplasmsHumansPancreasLiverSignal-To-Noise RatioCarcinoma, Pancreatic DuctalAdultMaleSpleenHealthy VolunteersFemaleImage Interpretation, Computer-AssistedReproducibility of Results

Stichwörter der Autor:innen

digital phantomdynamic contrast‐enhanced MRIextended Tofts modelk‐space sampling patternspancreatic cancerperfusion

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
  • Imaging and Biomarkers, Cancer Center Amsterdam, Amsterdam, The Netherlands.
  • Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Computational Imaging Group for MRI diagnostics and Therapy, Centre for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Department of Medical Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
  • Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands.

ORCID-Profile: Nienke P M Wassenaar, Eric M Schrauben

Förderung

  • KWF Kankerbestrijding

Zitieren

APA

Wassenaar, N. P. M., Gurney-Champion, O. J., van Schelt, A. S., Bruijnen, T., van Laarhoven, H. W. M., Stoker, J., Nederveen, A. J., Runge, J. H., & Schrauben, E. M. (2024). Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30213

Vancouver

Wassenaar NPM, Gurney-Champion OJ, van Schelt AS, Bruijnen T, van Laarhoven HWM, Stoker J, et al. Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30213

BibTeX
@article{Wassenaar2024,
  author = {Wassenaar, Nienke P M and Gurney-Champion, Oliver J and van Schelt, Anne-Sophie and Bruijnen, Tom and van Laarhoven, Hanneke W M and Stoker, Jaap and Nederveen, Aart J and Runge, Jurgen H and Schrauben, Eric M},
  title = {Optimizing pseudo‐spiral sampling for abdominal DCE MRI using a digital anthropomorphic phantom},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30213}
}
Kostenlos starten →