Assessment of Wrist-Worn Activity Tracker Accuracy for Measuring Sedentary Behavior in Outpatients With Cardiovascular Disease: Validation Study
JMIR Cardio · 2026-09-30 · 10 · e91104-e91104
DOI: 10.2196/91104 ↗At a glance
Validierungsstudie in JMIR Cardio, published online on 2026-09-30. Written by Koichi Naito and 6 co-authors. Institution: Department of Physical Therapy, Faculty of Medical Science, Nagoya Aoi University, 3-40 Shioji-cho, Mizuho-ku, Nagoya, 4678610, Japan, 81 52-838-5026. Major MEDLINE topics: Sedentary Behavior, Fitness Trackers, Cardiovascular Diseases, Outpatients. 39 references. The full text is freely available in PubMed Central.
Abstract (original language)
Background
Wearable monitoring of sedentary behavior is increasingly used in digital cardiovascular care, but the validity of consumer-grade wrist-worn trackers in older patients with cardiac issues is unclear.
Objective
This study aimed to evaluate the agreement between sedentary time measured by a consumer-grade wrist-worn tracker (Fitbit Inspire 3; Fitbit LLC) and a research-grade waist-worn accelerometer (ActiveStyle Pro HJA-750C; Omron Healthcare Co, Ltd) used as the comparator, in Japanese outpatients with cardiac issues under free-living conditions.
Methods
Fifty-one outpatients with heart failure (28/51, 55%) or ischemic heart disease (23/51, 45%; mean age 78.4, SD 9.0 years; 25/51, 49% male) simultaneously wore both devices for 7 consecutive days. Sedentary time was assessed within a standardized 12-hour daytime window (9 AM to 9 PM) at 1-minute epochs. Agreement was examined using Pearson correlation, Bland-Altman analysis (after confirming normality of the paired differences), Lin concordance correlation coefficient (CCC), and Cohen kappa for distribution-based tertile classification. A constant bias correction was applied, with leave-one-out cross-validation (LOOCV) used as an internal-consistency check on the stability of the sample mean bias. Moderators of the bias were explored using multivariable regression.
Results
Mean sedentary time within the 12-hour window was 497.9 (SD 86.5) minutes for the comparator and 559.9 (SD 84.3) minutes for the Fitbit. The devices were strongly correlated ( r =0.905, 95% CI 0.838‐0.945; P
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Physical Therapy, Faculty of Medical Science, Nagoya Aoi University, 3-40 Shioji-cho, Mizuho-ku, Nagoya, 4678610, Japan, 81 52-838-5026.
- Iwama Cardiovascular and Dental Clinic for Prevention and Care, Kitakatsuragi-gun, Japan.
- Department of Health Sciences, Graduate School of Medicine, Kobe University, Kobe, Japan.
- Faculty of Sport Sciences, Waseda University, Saitama, Japan.
- SapplyM, Inc., Tokyo, Japan.
Cite
APA
Naito, K., Izawa, K. P., Maeda, N., Kasai, Y., Tani, H., Kondo, M., & Iwama, H. (2026). Assessment of Wrist-Worn Activity Tracker Accuracy for Measuring Sedentary Behavior in Outpatients With Cardiovascular Disease: Validation Study. JMIR Cardio, 10, e91104-e91104. https://doi.org/10.2196/91104
Vancouver
Naito K, Izawa KP, Maeda N, Kasai Y, Tani H, Kondo M, et al. Assessment of Wrist-Worn Activity Tracker Accuracy for Measuring Sedentary Behavior in Outpatients With Cardiovascular Disease: Validation Study. JMIR Cardio. 2026;10:e91104-e91104. doi:10.2196/91104
BibTeX
@article{Naito2026,
author = {Naito, Koichi and Izawa, Kazuhiro P and Maeda, Noriaki and Kasai, Yuya and Tani, Haruna and Kondo, Misaki and Iwama, Hajime},
title = {Assessment of Wrist-Worn Activity Tracker Accuracy for Measuring Sedentary Behavior in Outpatients With Cardiovascular Disease: Validation Study},
journal = {JMIR Cardio},
year = {2026},
volume = {10},
pages = {e91104--e91104},
doi = {10.2196/91104}
}
EUVIMED