EUVIMEDSkopri EUVIMED
ValidierungsstudieOpen access

Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation

Hong Wang, Binbin Liu, Hui Zhang, Zheqi Zhang, Zhigeng Jin, Hao Wang, Yu-Tao Guo

JMIR Cardio · 2025-11-10 · 9 · e78075-e78075

DOI: 10.2196/78075 ↗

At a glance

Validierungsstudie in JMIR Cardio, published online on 2025-11-10. Written by Hong Wang and 6 co-authors. Institution: Department of Pulmonary Vessel and Thrombotic Disease, Sixth Medical Center, Chinese PLA General Hospital, 6 Fucheng Road, Haidian District, Beijing,…. Major MEDLINE topics: Atrial Fibrillation, Photoplethysmography, Machine Learning, Algorithms. Cited 10 times so far (Crossref); 33 references. The full text is freely available in PubMed Central.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Atrial fibrillation (AF) burden is associated with cardiovascular events such as stroke and heart failure. Recent advancements in photoplethysmography (PPG) technology have provided new insights into noninvasive and convenient AF burden detection.

Objective

This study aimed to establish an AF burden model based on smartwatch-monitored PPG technology to track the progression of AF.

Methods

This prospective pilot study (January 2024 to January 2025) at the Chinese PLA General Hospital enrolled patients with paroxysmal AF. Participants underwent simultaneous rhythm monitoring using smartwatch PPG and 24-hour Holter electrocardiogram monitoring (the gold standard). Five PPG-derived AF burden metrics were defined: (1) ratio of AF episode duration to total monitoring time (M1), (2) ratio of AF episode frequency to total measurements (M2), (3) AF episode density (M3), (4) AF episode variability (M4), and (5) proportion of rapid ventricular rate in AF episodes (>120 beats per minute; M5). Smartwatch PPG signals were collected once per minute. Sensitivity, specificity, accuracy, precision, and F 1 score were used to evaluate the PPG algorithm’s AF detection capability through comparison with the gold standard (24-hour Holter monitoring). The mean absolute error (MAE) and Spearman rank correlation coefficient ( r s ) were used to assess the correlation between the PPG-based AF burden metrics and the gold standard.

Results

A total of 145 participants with paroxysmal AF (n=96, 66.2% male; mean age 63.28, SD 14.23 years) were included. Compared to the gold standard, the PPG-based AF burden model demonstrated a sensitivity of 91.5% (95% CI 87.9%-95.1%), specificity of 97.2% (95% CI 95.9%-98.5%), precision of 92.9% (95% CI 88.6%-97.3%), accuracy of 93.3% (95% CI 88.2%-98.5%), and F 1 score of 90.5% (95% CI 86.3%-94.7%). The AF burden model exhibited strong discriminatory power in the test cohort (area under the curve=89.5%, 95% CI 89.4%‐89.7%). For M1, the MAE for the model of AF episode duration as a proportion of total monitoring time was 0.0400 ( P =.008), with a correlation coefficient ( r s ) of 0.8788 ( P

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationPhotoplethysmographyMachine LearningAlgorithmsHumansMaleFemaleProspective StudiesMiddle AgedAgedPilot ProjectsElectrocardiography, Ambulatory

Author keywords

arrhythmiaatrial fibrillationatrial fibrillation burdenphotoplethysmographywearable devices

Authors and institutions

  • Department of Pulmonary Vessel and Thrombotic Disease, Sixth Medical Center, Chinese PLA General Hospital, 6 Fucheng Road, Haidian District, Beijing, 100048, China, +86-10-66957703.
  • Graduate School of PLA General Hospital, Beijing, China.
  • Department of Cardiology, Second Medical Centre, National Clinical Research Centre for Geriatric Diseases, Chinese PLA General Hospital, Beijing, China.

Cite

APA

Wang, H., Liu, B., Zhang, H., Zhang, Z., Jin, Z., Wang, H., & Guo, Y. T. (2025). Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation. JMIR Cardio, 9, e78075-e78075. https://doi.org/10.2196/78075

Vancouver

Wang H, Liu B, Zhang H, Zhang Z, Jin Z, Wang H, et al. Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation. JMIR Cardio. 2025;9:e78075-e78075. doi:10.2196/78075

BibTeX
@article{Wang2025,
  author = {Wang, Hong and Liu, Binbin and Zhang, Hui and Zhang, Zheqi and Jin, Zhigeng and Wang, Hao and Guo, Yu-Tao},
  title = {Photoplethysmography-Based Machine Learning Approaches for Atrial Fibrillation Burden: Algorithm Development and Validation},
  journal = {JMIR Cardio},
  year = {2025},
  volume = {9},
  pages = {e78075--e78075},
  doi = {10.2196/78075}
}
Start for free →