Pulsed Field Versus Contact Force Radiofrequency Ablation in Persistent Atrial Fibrillation: A Meta‐Analysis
Pacing and Clinical Electrophysiology · 01.11.2026
DOI: 10.1111/pace.70480 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Pacing and Clinical Electrophysiology, online erschienen am 01.11.2026. Verfasst von Arsh Rehman und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, State Key Laboratory of Organ Failure Research, Nanfang Hospital, Southern Medical University, Guangzhou, China. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Clinical Research Fund of NanFang Hospital, Southern Medical University.
Abstract (Originalsprache)
Background
Atrial fibrillation (AF) remains a challenging arrhythmia to manage, and catheter ablation is a cornerstone therapy. Pulsed Field Ablation (PFA) has recently emerged as a novel non‐thermal alternative to Contact Force Radiofrequency (CF‐RF) ablation. This meta‐analysis compares the efficacy, safety, and procedural efficiency of PFA versus CF‐RF in patients with persistent atrial fibrillation.
Methods
A systematic review and meta‐analysis were conducted using randomized controlled trials and cohort studies identified from MEDLINE, Embase, and Cochrane databases. Primary outcomes included 12‐month freedom from atrial arrhythmia (AF, atrial flutter, or atrial tachycardia), procedure duration, fluoroscopy time, and major complications. Subgroup analyses were performed based on PFA device type (Farapulse vs. HT‐9000Pro) and patient characteristics, including left atrial size and AF duration.
Results
Seventeen studies met inclusion criteria. PFA was associated with significantly higher 12‐month freedom from atrial arrhythmia compared with CF‐RF (OR = 1.36, 95% CI 1.26–1.47, p < 0.001). Procedure time was markedly shorter with PFA (MD = −40.5 minutes, p < 0.001), while fluoroscopy time also showed a significant reduction (MD = −1.8 minutes, p = 0.001). Major complications were significantly lower with PFA (1.2% vs. 2.8%; OR = 0.44, 95% CI 0.35–0.57, p < 0.001).
Conclusion
In persistent AF, PFA, demonstrates superior efficacy, safety, and procedural efficiency compared with CF‐RFA, supporting its role as a potential first‐line ablation strategy. Larger multicenter trials with long‐term follow‐up are needed to confirm durability and device‐specific outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, State Key Laboratory of Organ Failure Research, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Aurora Medical Center, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China.
- Department of Cardiac Surgery, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, P.R. China.
- Department of Cardiovascular Medicine, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Department of Biostatistics, Guangdong Provincial Key Laboratory of Tropical Disease Research, School of Public Health, Southern Medical University, Guangzhou, Guangdong, P.R. China.
- HCA Florida Heart Institute, Largo, Florida, USA.
Förderung
- Clinical Research Fund of NanFang Hospital
- Southern Medical University
Zitieren
APA
Rehman, A., Sun, Z., Khalid, M., Deng, H., Chen, Y., An, S., Xiang, K., Zhang, J., Li, X., Makhsham, F. M. A., Huang, S., Lin, H., He, L., Chen, Y., Chen, G., & Wang, Y. (2026). Pulsed Field Versus Contact Force Radiofrequency Ablation in Persistent Atrial Fibrillation: A Meta‐Analysis. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70480
Vancouver
Rehman A, Sun Z, Khalid M, Deng H, Chen Y, An S, et al. Pulsed Field Versus Contact Force Radiofrequency Ablation in Persistent Atrial Fibrillation: A Meta‐Analysis. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70480
BibTeX
@article{Rehman2026,
author = {Rehman, Arsh and Sun, ZhuHua and Khalid, Muhammad and Deng, HaoZhe and Chen, Yuanyuan and An, Shengli and Xiang, Kun and Zhang, JianQin and Li, XinZhong and Makhsham, Fahd Mohammed Abdullah and Huang, SenLin and Lin, HaiRuo and He, LiWei and Chen, YanMei and Chen, GuoJun and Wang, YueGang},
title = {Pulsed Field Versus Contact Force Radiofrequency Ablation in Persistent Atrial Fibrillation: A Meta‐Analysis},
journal = {Pacing and Clinical Electrophysiology},
year = {2026},
doi = {10.1111/pace.70480}
}
EUVIMED