EUVIMEDAtrasti EUVIMED
CrossrefInformacijos kortelė

Diagnostic Accuracy of 12‐Lead ECG Algorithms for Accessory Pathway Localization in WPW: A Meta‐Analysis

Elsayed S. Moubarak, Ahmed Farid Gadelmawla, Almothana Manasrah, Anas Mansour, Mohamed S. Elgendy, Omar Elkoumi, Husam Abu Suilik, Suhaib El Khatib, Naser Albekaen, Ahmed Moustafa, Rania Samir, Islam Saboukh, Nadica Trajkovska, Angeliki Darma, Vanessa Sciacca, Thomas Fink, Moneeb Khalaph, Christian Sohns, Philipp Sommer, Hassan El‐Shirbiny

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1748-1761

DOI: 10.1111/pace.70387 ↗
SantraukaBibliografiniai duomenys

Santrauka

ABSTRACT Background In Wolff–Parkinson–White (WPW) syndrome, accurate localization of accessory pathways before catheter ablation can improve procedural planning and efficiency. Several 12‐lead electrocardiographic (ECG) algorithms have been proposed, but their diagnostic performance has not been consistently established. We performed a systematic review and meta‐analysis to assess the accuracy of ECG‐based algorithms for accessory pathway localization in manifest WPW. Methods Following PRISMA‐DTA recommendations, PubMed, EMBASE, Cochrane CENTRAL, Web of Science, and Scopus were searched from January 1990 to January 2026. Studies enrolling adult or pediatric patients with manifest pre‐excitation who underwent electrophysiological study (EPS) and catheter ablation were included. Successful localization during EPS/ablation served as the reference standard. Random‐effects models were used to calculate pooled diagnostic accuracy, sensitivity, specificity, and diagnostic odds ratios (DOR). Summary receiver operating characteristic and leave‐one‐out sensitivity analyses were also performed. Results Seventeen studies involving 3159 patients met inclusion criteria. The pooled diagnostic accuracy of ECG algorithms was 0.91 (95% CI 0.85–0.94), although heterogeneity was substantial (I 2 = 91.4%). Pooled sensitivity was 0.87 (95% CI 0.73–0.94), and pooled specificity was 0.98 (95% CI 0.95–0.99; I 2 = 0%). The pooled DOR was 297.17 (95% CI 46.33–1906.19; p

Jūsų darbui tinkamos žinios.

Nuo nemokamos pradžios ir asmeninės literatūros paieškos iki viso Research Suite.

Peržiūrėti tarifus →

Ar įtraukti visi leidėjų pilnieji tekstai?

Ne. Bibliografiniai įrašai, santraukos ir pilnieji tekstai yra skirtingas turinys. Ar pilnasis tekstas prieinamas, priklauso nuo šaltinio, Open Access ir jūsų turimų licencijų. EUVIMED planas nepakeičia papildomų leidėjų teisių.

Peržiūrėti tarifus →