EUVIMEDSkopri EUVIMED
CrossrefKarta ta’ informazzjoni

12‐Month Clinical Outcomes Using a Variable‐Loop Circular Catheter for PFA in a Chinese Atrial Fibrillation Population

Hailong Tao, Heng Cai, Hua Fu, Shaowen Liu, Songwen Chen, Lianjun Gao, Xiaomeng Yin, Yumei Xue, Hongtao Liao, Rui Zeng, Kaijun Cui, Jianzeng Dong

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1851-1861

DOI: 10.1111/pace.70294 ↗
AstrattDettalji biblijografiċi

Astratt

ABSTRACT Background The variable‐loop circular catheter (VLCC) showed promising outcomes in European and US studies, but evidence is limited in Asian populations. afIRE trial assessed 12‐month safety and effectiveness of the VLCC in Chinese patients with symptomatic, drug‐refractory paroxysmal atrial fibrillation (AF). Methods AfIRE was a prospective, multicenter, single‐arm trial for adults undergoing first‐time pulmonary vein isolation (PVI) with the VLCC. Primary effectiveness was 12‐month freedom from atrial arrhythmia recurrence (systematically assessed by electrocardiogram and Holter monitoring at 3‐, 6‐, and 12‐months post‐ablation or when symptomatic), repeat ablation, procedural failure, or Class I/III antiarrhythmic drug use. Safety was defined by incidence of primary adverse events (PAEs). Results Of 142 patients enrolled, 123 (mean age 57.0 years, 45.5% female) comprised the main‐stage cohort (patients treated with the VLCC after roll in). Median procedure, pulsed field ablation (PFA), and fluoroscopy times were 115.0, 36.1, and 5.0 min, respectively. Acute PVI was achieved in all patients, with 89.4% without acute reconnection and 11.4% undergoing non‐PV ablation. Twelve‐month primary effectiveness success and freedom from symptomatic recurrence were 74.8% and 87.0%, respectively. Safety was favorable, with PAEs in 2 patients (1.6%; vascular complications; unlikely device‐related). Multivariable analysis of the primary endpoint showed that preserved left ventricular ejection fraction (≥ 60%) was associated with 86% reduction in odds of 12‐month atrial arrhythmia recurrence; diabetes, ≥ 9 symptomatic AF episodes, and < 48 valid PFA applications (16 ablations) numerically increased odds of recurrence. Conclusion The first Asian VLCC experience demonstrated favorable 12‐month effectiveness and excellent safety, reinforcing reproducibility across global AF populations. Clinical Trial Registration NCT05552963

Għarfien li jaqbel max-xogħol tiegħek.

Minn bidu b’xejn u riċerka personali tal-letteratura sal-Research Suite sħiħa.

Ara t-tariffi →

Il-full texts kollha tal-pubblikaturi huma inklużi?

Le. Ir-referenzi biblijografiċi, l-astratti u t-testi sħaħ huma kontenuti differenti. Jekk test sħiħ huwiex disponibbli jiddependi mis-sors, Open Access u l-liċenzji eżistenti tiegħek. Pjan ta’ EUVIMED ma jissostitwix drittijiet addizzjonali tal-pubblikaturi.

Ara t-tariffi →