EUVIMEDObjevte EUVIMED
CrossrefInformační karta

Simultaneous Tricuspid Valve Replacement and Left Bundle Branch Area Pacing With Surgical Lead Refixation

Kentaro Goto, Shinsuke Miyazaki, Ayaka Usui, Hironobu Sakurai, Eiki Nagaoka, Tomoyuki Fujita, Tetsuo Sasano

Pacing and Clinical Electrophysiology · 2026-11 · 49 (11) · 1869-1872

DOI: 10.1111/pace.70292 ↗
AbstraktBibliografické údaje

Abstrakt

ABSTRACT Background The importance of managing tricuspid regurgitation (TR) has been increasingly recognized, and tricuspid valve replacement (TVR) is now performed more frequently. Conduction system pacing (CSP), including left bundle branch area pacing (LBBAP), offers substantial benefits by improving left ventricular (LV) electrical synchrony. However, combining these two strategies is challenging. Case A 58‐year‐old man underwent dual‐chamber pacemaker implantation for complete atrioventricular block. Five years later, he developed severe LV dysfunction due to right ventricular (RV) apical pacing–induced cardiomyopathy. Upgrade to conventional cardiac resynchronization therapy resulted in a persistently prolonged QRS duration (150 msec) and modest improvement in LV ejection fraction (LVEF, 35%). RV lead–related TR progressively worsened, leading to biventricular heart failure. Although tricuspid valve repair was performed, severe TR recurred. Following heart team discussion, both CSP upgrade and TVR were deemed necessary without delay. An LBBAP lead was implanted the day before surgery as an “electrophysiological anchor.” During TVR, the lead was dislodged; however, the surgeon identified the insertion (“anchor”) site, reinserted the lead, and secured it by jailing it outside the prosthetic valve in a protective position. Postoperatively, the pacing threshold improved (1.5 V@0.4 ms to 0.75V@0.4 ms) with QRS narrowing (135 to 125 ms). At three months, heart failure symptoms were markedly relieved, LVEF improved to 50%, and lead parameters remained stable. Conclusion Although jailing a lead with a prosthetic valve requires great caution to ensure long‐term lead survival, we successfully combined LBBAP and surgical TVR with intraoperative refixation.

Znalosti, které odpovídají vaší práci.

Od bezplatného začátku přes osobní rešerše literatury až po kompletní Research Suite.

Zobrazit tarify →

Jsou zahrnuty všechny plné texty vydavatelů?

Ne. Bibliografické záznamy, abstrakty a plné texty jsou různé typy obsahu. To, zda je plný text dostupný, závisí na zdroji, Open Access a vašich stávajících licencích. Tarif EUVIMED nenahrazuje dodatečná vydavatelská práva.

Zobrazit tarify →