EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Very High‐Power Short‐Duration Ablation for Premature Ventricular Complexes From Sites With Suboptimal Catheter Stability

Heather Wheat, Kelly Arps iD, Amrish Deshmukh iD, Michael Ghannam, Frank Bogun, Jackson J Liang

Journal of Cardiovascular Electrophysiology · 2026-03 · 37 (3) · 652-654

DOI: 10.1111/jce.70264 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 20.01.2026. Verfasst von Heather Wheat und 5 weiteren Autor:innen. Beteiligte Einrichtung: Electrophysiology section, Division of Cardiology, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Ventricular Premature Complexes, Catheter Ablation, Cardiac Catheters, Papillary Muscles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

While very high‐power short‐duration (vHPSD) ablation has been shown to be safe and effective for ablation of atrial fibrillation, the utility of vHPSD ablation for targeting premature ventricular complexes (PVCs) remains unclear. We aimed to describe our experience of PVC ablation using vHPSD ablation targeting areas with suboptimal catheter contact. Methods and Results We included 8 patients (mean age 66.5 ± 11.3 years, 77% female gender, mean LV ejection fraction 52.8 ± 8.2%, baseline PVC burden 23.3 ± 10.1% [range 9–41%]) with PVCs originating from intracavitary structures [LV papillary muscle(s) ( n = 7), RV papillary muscle ( n = 1)] which were successfully eliminated with vHPSD ablation using a temperature‐controlled ablation catheter (QDOT‐MICRO; Biosense Webster, Irvine, California, USA) with lesions delivered at 90 W for 4 seconds using QMODE+ mode. Mean QMODE+ lesions delivered in each patient was 28 ± 15.1 with a mean total QMODE+ RF time of 112 ± 60.4 seconds. There were no procedural complications. Durable PVC suppression was confirmed on post‐ablation monitoring in all patients (mean post‐ablation PVC burden < 1% [range 0–2.3%]).

Conclusion

Ablation with vHPSD using a temperature‐controlled radiofrequency ablation catheter can be safe and effective for PVC ablation in regions with poor catheter stability such as RV and LV papillary muscles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular Premature ComplexesCatheter AblationCardiac CathetersPapillary MusclesHumansFemaleTime FactorsTreatment OutcomeMiddle AgedAgedMaleHeart RateAction Potentials

Autor:innen und Institutionen

  • Electrophysiology section, Division of Cardiology, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Kelly Arps, Amrish Deshmukh

Zitieren

APA

Wheat, H., Arps, K., Deshmukh, A., Ghannam, M., Bogun, F., & Liang, J. J. (2026). Very High‐Power Short‐Duration Ablation for Premature Ventricular Complexes From Sites With Suboptimal Catheter Stability. Journal of Cardiovascular Electrophysiology, 37(3), 652-654. https://doi.org/10.1111/jce.70264

Vancouver

Wheat H, Arps K, Deshmukh A, Ghannam M, Bogun F, Liang JJ. Very High‐Power Short‐Duration Ablation for Premature Ventricular Complexes From Sites With Suboptimal Catheter Stability. Journal of Cardiovascular Electrophysiology. 2026;37(3):652-654. doi:10.1111/jce.70264

BibTeX
@article{Wheat2026,
  author = {Wheat, Heather and Arps, Kelly and Deshmukh, Amrish and Ghannam, Michael and Bogun, Frank and Liang, Jackson J},
  title = {Very High‐Power Short‐Duration Ablation for Premature Ventricular Complexes From Sites With Suboptimal Catheter Stability},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  volume = {37},
  number = {3},
  pages = {652--654},
  doi = {10.1111/jce.70264}
}
Kostenlos starten →