EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation

Masahide Harada, Yuji Motoike, Yoshihiro Nomura, Asuka Nishimura, Eiichi Watanabe, Yukio Ozaki, Hideo Izawa

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70246 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Masahide Harada und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Fujita Health University, Toyoake, Aichi, Japan. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation, Cardiac Catheters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

EnSite X provides a module to filter oscillated generator impedance signals due to cardiac beating/respiration (averaged impedance drop, AID). TactiFlex ablation catheter Sensor Enabled (TFSE) is the latest product to incorporate a contact‐force sensor with a flexible tip but without lesion‐estimating parameters.

Methods

To examine if AID estimates lesion formation, AID were compared between ablated lesions ( n = 1687) with and without conduction gaps (CGs) after first‐pass pulmonary vein isolation (PVI) using TFSE in atrial fibrillation (AF) patients ( n = 20). The clinical efficacy of AID‐guided PVI was evaluated in another subset of AF patients ( n = 30).

Results

CGs were observed in 45 points (CG[+]) but not in 1642 points (CG[−]). CG[+] had lower %AID (=absolute AID/initial impedance, p < 0.0001) than CG[−]. Decrease of bipolar voltage amplitude during radiofrequency application was linearly correlated with %AID ( R 2 = 0.785, p < 0.05). In receiver operating curve analysis, the cutoff values of %AID and unfiltered generator impedance drop for predicting CG was 9.33% and 11.0 Ω, respectively; %AID had significantly higher area under the curve than unfiltered generator impedance drop (0.761 vs. 0.627, p < 0.05). In swine heart experiments, %AID was correlated with lesion volume ( R 2 = 0.711, p < 0.05). In another subset of AF patients, success rate of first‐pass isolation in %AID ( ≥ 9%)‐guided PVI was 90% for LPV and 90% for RPV. The 1‐year event‐free rate of atrial tachyarrhythmias was 82%.

Conclusion

AID would improve the usability of impedance drop as an end point for RF application. %AID‐guided PVI using TFSE would be effective in AF patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsCatheter AblationCardiac CathetersHumansFemaleAction PotentialsElectric ImpedanceMaleTreatment OutcomeMiddle AgedAnimalsTime FactorsEquipment DesignHeart RateAgedPredictive Value of TestsRecurrence

Stichwörter der Autor:innen

atrial fibrillationimpedance droppulmonary vein isolationradiofrequency catheter ablation

Autor:innen und Institutionen

  • Department of Cardiology, Fujita Health University, Toyoake, Aichi, Japan.
  • Department of Cardiology, Fujita Health University Bantane Hospital, Nagoya, Aichi, Japan.
  • Department of Cardiology, Fujita Health University Okazaki Medical Center, Okazaki, Aichi, Japan.

Zitieren

APA

Harada, M., Motoike, Y., Nomura, Y., Nishimura, A., Watanabe, E., Ozaki, Y., & Izawa, H. (2026). Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70246

Vancouver

Harada M, Motoike Y, Nomura Y, Nishimura A, Watanabe E, Ozaki Y, et al. Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70246

BibTeX
@article{Harada2026,
  author = {Harada, Masahide and Motoike, Yuji and Nomura, Yoshihiro and Nishimura, Asuka and Watanabe, Eiichi and Ozaki, Yukio and Izawa, Hideo},
  title = {Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70246}
}
Kostenlos starten →