Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.70237 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Amato Santoro und 23 weiteren Autor:innen. Beteiligte Einrichtung: Azienda Ospedaliera Universitaria Senese, Siena, Italy. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Heart Rate, Bundle of His, Pacemaker, Artificial. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy. However, its feasibility and safety using conventional stylet‐driven leads (SDL) such as INGEVITY+ remain under investigation.
Objective
To evaluate the clinical performance, safety, and follow‐up outcomes of LBBAP using the INGEVITY+ lead in a real‐world electrophysiology setting.
Methods
From 2021 to 2024, 207 consecutive patients underwent LBBAP implant attempts using the INGEVITY+ lead across 19 centers. Of these, 146 had bradycardia indications, and 61 had heart failure indications. A control group of 200 patients received standard right ventricular (RV) pacing with the same lead. Procedural outcomes, electrical parameters, complications, and mid‐term lead performance were assessed.
Results
LBBAP was successfully achieved in 201 (97%) cases. Procedural and fluoroscopy times were slightly longer for LBBAP than for RV pacing. Acute complications included one helix fracture, one atrioventricular block, and one septal perforation. During a median follow‐up of 9 months, no lead fractures were reported; lead dislodgment occurred in three cases. Kaplan–Meier analysis showed no significant difference in time to first lead‐related complication between the LBBAP and RV pacing groups (hazard ratio: 4.69, 95%CI: 0.63–34.90, p = 0.139). Electrical performance remained stable, with 98% of retained leads maintaining capture thresholds ≤ 2 V and 92% with sensed amplitudes ≥ 5 mV.
Conclusions
LBBAP using the INGEVITY + SDL is feasible and safe in clinical practice, with excellent implant success and stable mid‐term electrical performance. These findings support its use as a viable conduction system pacing strategy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Azienda Ospedaliera Universitaria Senese, Siena, Italy.
- S. Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy.
- Ospedale del Mare, Naples, Italy.
- Federico II University of Naples, Naples, Italy.
- Ospedale Santa Maria della Pietà, Nola, Italy.
- Ospedale Maggiore di Lodi, Lodi, Italy.
ORCID-Profile: Amato Santoro, Paolo Liberato Magliano, Gabriele Dell'Era, Carmelo La Greca
Zitieren
APA
Santoro, A., Ziacchi, M., Calvanese, R., Rapacciuolo, A., Volpicelli, M., Poggio, L., Nocerino, P., Castagno, D., Bianchi, V., Magliano, P. L., Dell'Era, G., Mandurino, C., Mirizzi, G., Savarese, G., Marinaccio, L., La Greca, C., Covino, G., Zingarini, G., Varalda, M., …, & Bertini, M. (2025). Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70237
Vancouver
Santoro A, Ziacchi M, Calvanese R, Rapacciuolo A, Volpicelli M, Poggio L, et al. Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70237
BibTeX
@article{Santoro2025,
author = {Santoro, Amato and Ziacchi, Matteo and Calvanese, Raimondo and Rapacciuolo, Antonio and Volpicelli, Mario and Poggio, Luca and Nocerino, Pasquale and Castagno, Davide and Bianchi, Valter and Magliano, Paolo Liberato and Dell'Era, Gabriele and Mandurino, Cosimo and Mirizzi, Gianluca and Savarese, Gianluca and Marinaccio, Leonardo and La Greca, Carmelo and Covino, Gregorio and Zingarini, Gianluca and Varalda, Marco and Vitali, Francesco and Baiocchi, Claudia and Campari, Monica and Valsecchi, Sergio and Bertini, Matteo},
title = {Implantation Success, Electrical Performance, and Safety of an Active Fixation Stylet‐Driven Lead for LBBAP in Clinical Practice: A Multicenter Experience},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.70237}
}
EUVIMED