Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation
Clinical Cardiology · 2025
DOI: 10.1002/clc.70116 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Cardiology, 2025. Verfasst von Jieruo Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cardiac Pacing, Artificial, Heart Ventricles, Pacemaker, Artificial. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research received funding from the Clinical Technology Innovation Project of Beijing Hospital Management Center..
Abstract (Originalsprache)
Background
Traditional right ventricular pacing (RVP) can lead to asynchronous cardiac mechanical contractions and increase the risk of atrial fibrillation (AF). This study aimed to compare the occurrence of new‐onset AF and the progression of AF between novel physiological pacing—left bundle branch area pacing (LBBAP) and RVP with a long‐term follow‐up. Methods and Results Patients with a dual‐chamber permanent pacemaker initial implantation, no history of persistent AF, and an expected high proportion of ventricular pacing (VP ≥ 20%) were included in this retrospective cohort study (LBBAP, n = 122; RVP, n = 166). The pacing QRS duration (QRSd) of the LBBAP was significantly shorter than that of the RVP (113 ± 22 vs. 140 ± 27 ms, p < 0.001), while the intrinsic QRSd values from the two groups were comparable. During a mean follow‐up of 21.9 ± 9.4 months, the composite outcome of postoperative new‐onset AF or AF progression was higher in the RVP group than in the LBBAP group (RVP HR 2.62, 95%CI 1.21–5.67, p = 0.014). Left ventricular end‐diastolic diameter (LVEDD) levels decreased in the LBBAP group at 1 year follow‐up (50 ± 6 vs. baseline 48 ± 6, p = 0.002).
Conclusions
In a mean follow‐up period of 2 years, compared to RVP, LBBAP patients with VP ≥ 20% had a decreased risk of occurrence and progression of AF events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Förderung
- This research received funding from the Clinical Technology Innovation Project of Beijing Hospital Management Center.
Zitieren
APA
Chen, J., Wang, Z., Hang, F., Sun, W., Li, H., & Wu, Y. (2025). Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation. Clinical Cardiology. https://doi.org/10.1002/clc.70116
Vancouver
Chen J, Wang Z, Hang F, Sun W, Li H, Wu Y. Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation. Clinical Cardiology. 2025. doi:10.1002/clc.70116
BibTeX
@article{Chen2025,
author = {Chen, Jieruo and Wang, Zefeng and Hang, Fei and Sun, Weiping and Li, Haiwei and Wu, Yongquan},
title = {Long‐Term Effects of Left Bundle Branch Area Pacing Versus Traditional Right Ventricular Pacing on Atrial Fibrillation After Dual‐Chamber Pacemaker Implantation},
journal = {Clinical Cardiology},
year = {2025},
doi = {10.1002/clc.70116}
}
EUVIMED