Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Christian Georgi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Brandenburg Medical School (MHB) Theodor Fontane, University Hospital Heart Center Brandenburg, Neuruppin, Germany. Hauptthemen laut MEDLINE: Atrial Fibrillation, Recurrence, Catheter Ablation, Predictive Value of Tests. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Left atrial (LA) low voltage areas (LVA) are a controversial target in atrial fibrillation ablation procedures. However, LVA and LA volume are good predictors of arrhythmia recurrence in ablation‐naïve patients. Their predictive value in progressively diseased pre‐ablated atria is uncertain.
Methods
Consecutive patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT), who were scheduled for repeat LA ablation, were enrolled in the prospective Bernau ablation registry between 2016 and 2020. All patients received a complete LA ultrahigh‐density map before ablation. Maps were analyzed for LA size, LVA percentage and distribution. The predictive value of demographic, anatomic, and mapping variables on AF recurrence was analyzed.
Results
160 patients (50.6% male, 1.3 pre‐ablations, 60% persistent AF) with complete LA voltage maps were included. Mean follow‐up time was 16 ± 11 months. Mean recorded electrograms (EGMs) per map were 9754 ± 5808, mean LA volume was 176.1 ± 35.9 ml and mean rate of LVAs 30 s was 55.6%. Patients with recurrence had a significant higher percentage of LVAs (40.0% vs. 18.8%, p < .001) but no relevant difference in LA volume (172 vs. 178 mL, p = .299). ROC curves revealed LVA as a good predictor for recurrence (AUC = 0.79, p < .001) and a cut‐off of 22% LVAs with highest sensitivity (73.0%) and specificity (71.8%). Based on this cut off, event free survival was significantly higher in the Low LVA group ( p < .01).
Conclusion
Total LVA percentage has a good predictive power on arrhythmia recurrence in a cohort of advanced scarred left atria in repeat procedures independent of the applied ablation strategy. Left atrial volume seems to have minor impact on the rhythm outcome in our study cohort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Brandenburg Medical School (MHB) Theodor Fontane, University Hospital Heart Center Brandenburg, Neuruppin, Germany.
- Faculty of Health Sciences Brandenburg, Neuruppin, Germany.
- Institute of Social Medicine and Health System Research, Otto von Guericke University Magdeburg, Magdeburg, Germany.
ORCID-Profile: Christian Georgi
Zitieren
APA
Georgi, C., Bannehr, M., Lochmann, M., Reiners, D., Haase-Fielitz, A., Butter, C., & Seifert, M. (2024). Left atrial low‐voltage areas, but not volume, predict the recurrence of atrial fibrillation in repeat ablation procedures. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16266
Vancouver
Georgi C, Bannehr M, Lochmann M, Reiners D, Haase-Fielitz A, Butter C, et al. Left atrial low‐voltage areas, but not volume, predict the recurrence of atrial fibrillation in repeat ablation procedures. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16266
BibTeX
@article{Georgi2024,
author = {Georgi, Christian and Bannehr, Marwin and Lochmann, Marlene and Reiners, David and Haase-Fielitz, Anja and Butter, Christian and Seifert, Martin},
title = {Left atrial low‐voltage areas, but not volume, predict the recurrence of atrial fibrillation in repeat ablation procedures},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2024},
doi = {10.1111/jce.16266}
}
EUVIMED