EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

How automated techniques ease functional assessment of the fetal heart: Applicability of two‐dimensional speckle‐tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®

Jann Lennard Scharf iD, Christoph Dracopoulos, Michael Gembicki, Achim Rody, Amrei Welp, Jan Weichert iD

Echocardiography · 2024

DOI: 10.1111/echo.15833 ↗

At a glance

Journal article in Echocardiography, 2024. Written by Jann Lennard Scharf and 5 co-authors. Institution: Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Lübeck, Germany. Major MEDLINE topics: Fetal Heart, Ultrasonography, Prenatal, Echocardiography. Cited 5 times so far (Crossref); 82 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Prenatal echocardiographic assessment of fetal cardiac function has become increasingly important. Fetal two‐dimensional speckle‐tracking echocardiography (2D‐STE) allows the determination of global and segmental functional cardiac parameters. Prenatal diagnostics is relying increasingly on artificial intelligence, whose algorithms transform the way clinicians use ultrasound in their daily workflow. The purpose of this study was to demonstrate the feasibility of whether less experienced operators can handle and might benefit from an automated tool of 2D‐STE in the clinical routine.

Methods

A total of 136 unselected, normal, singleton, second‐ and third‐trimester fetuses with normofrequent heart rates were examined by targeted ultrasound. 2D‐STE was performed separately by beginner and expert semiautomatically using a GE Voluson E10 (FetalHQ®, GE Healthcare, Chicago, IL). Several fetal cardiac parameters were calculated (end‐diastolic diameter [ED], sphericity index [SI], global longitudinal strain [EndoGLS], fractional shortening [FS]) and assigned to gestational age (GA). Bland‐Altman plots were used to test agreement between both operators.

Results

The mean maternal age was 33 years, and the mean maternal body mass index prior to pregnancy was 24.78 kg/m 2 . The GA ranged from 16.4 to 32.0 weeks (average 22.9 weeks). Averaged endoGLS value of the beginner was ‐18.57% ± 6.59 percentage points (pp) for the right and ‐19.58% ± 5.63 pp for the left ventricle, that of the expert ‐14.33% ± 4.88 pp and ‐16.37% ± 5.42 pp. With increasing GA, right ventricular endoGLS decreased slightly while the left ventricular was almost constant. The statistical analysis for endoGLS showed a Bland‐Altman‐Bias of ‐4.24 pp ± 8.06 pp for the right and ‐3.21 pp ± 7.11 pp for the left ventricle. The Bland‐Altman‐Bias of the ED in both ventricles in all analyzed segments ranged from ‐.49 mm ± 1.54 mm to ‐.10 mm ± 1.28 mm, that for FS from ‐.33 pp ± 11.82 pp to 3.91 pp ± 15.56 pp and that for SI from ‐.38 ± .68 to ‐.15 ± .45.

Conclusions

Between both operators, our data indicated that 2D‐STE analysis showed excellent agreement for cardiac morphometry parameters (ED and SI), and good agreement for cardiac function parameters (EndoGLS and FS). Due to its complexity, the application of fetal 2D‐STE remains the domain of scientific‐academic perinatal ultrasound and should be placed preferably in the hands of skilled operators. At present, from our perspective, an implementation into clinical practice “on‐the‐fly” cannot be recommended.

Subjects

MeSH terms (MEDLINE)

Fetal HeartUltrasonography, PrenatalEchocardiographyHumansFemalePregnancyAdultReproducibility of ResultsFeasibility StudiesGestational Age

Author keywords

artificial intelligenceautomationcardiac functionfetal echocardiographyfetalHQ®speckle‐tracking

Authors and institutions

  • Department of Gynecology and Obstetrics, Division of Prenatal Medicine, University Hospital of Schleswig-Holstein, Lübeck, Germany.

ORCID profiles: Jann Lennard Scharf, Jan Weichert

Cite

APA

Scharf, J. L., Dracopoulos, C., Gembicki, M., Rody, A., Welp, A., & Weichert, J. (2024). How automated techniques ease functional assessment of the fetal heart: Applicability of two‐dimensional speckle‐tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®. Echocardiography. https://doi.org/10.1111/echo.15833

Vancouver

Scharf JL, Dracopoulos C, Gembicki M, Rody A, Welp A, Weichert J. How automated techniques ease functional assessment of the fetal heart: Applicability of two‐dimensional speckle‐tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®. Echocardiography. 2024. doi:10.1111/echo.15833

BibTeX
@article{Scharf2024,
  author = {Scharf, Jann Lennard and Dracopoulos, Christoph and Gembicki, Michael and Rody, Achim and Welp, Amrei and Weichert, Jan},
  title = {How automated techniques ease functional assessment of the fetal heart: Applicability of two‐dimensional speckle‐tracking echocardiography for comprehensive analysis of global and segmental cardiac deformation using fetalHQ®},
  journal = {Echocardiography},
  year = {2024},
  doi = {10.1111/echo.15833}
}
Start for free →