EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Making RF coils MR ‐invisible by additive manufacturing using magnetically filled polymer

Markus Weiger iD, Johan Overweg, Amelie Viol, Lauro Singenberger, Thomas Schmid, Emily Louise Baadsvik iD, Klaas Paul Pruessmann iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Markus Weiger und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Polymers. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Short‐T 2 MRI is sensitive not only to targeted tissues but also to signals from materials in RF coils, which can lead to image background artifacts. Current solutions to this problem either compromise imaging performance or impose restrictions on coil design. The goal of the present work is to make RF coils MR‐invisible without such drawbacks.

Methods

Effective spoiling of unwanted signals from the housing of RF coils is achieved by filling the material used to construct the housing with magnetic particles. This concept is demonstrated by creating coil formers through additive manufacturing with custom filaments made from magnetite‐filled polymer.

Results

Unwanted signals from the RF coil are effectively eliminated by using coil formers made from magnetically filled polymer. In this fashion, background‐free short‐T 2 imaging is enabled.

Conclusion

Making RF coils MR‐invisible by using magnetically filled materials simplifies coil design and manufacturing and renders the alteration of MR sequences unnecessary, thereby improving the performance of MRI of tissues with short T 2 s.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPolymersEquipment DesignPhantoms, ImagingRadio WavesArtifacts

Stichwörter der Autor:innen

3D printingPLAUTEZTEmagnetiteshort T2

Substanzen

Polymers

Autor:innen und Institutionen

  • Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.
  • Uelzen, Germany.

ORCID-Profile: Markus Weiger, Emily Louise Baadsvik, Klaas Paul Pruessmann

Zitieren

APA

Weiger, M., Overweg, J., Viol, A., Singenberger, L., Schmid, T., Baadsvik, E. L., & Pruessmann, K. P. (2026). Making RF coils MR ‐invisible by additive manufacturing using magnetically filled polymer. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70115

Vancouver

Weiger M, Overweg J, Viol A, Singenberger L, Schmid T, Baadsvik EL, et al. Making RF coils MR ‐invisible by additive manufacturing using magnetically filled polymer. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70115

BibTeX
@article{Weiger2026,
  author = {Weiger, Markus and Overweg, Johan and Viol, Amelie and Singenberger, Lauro and Schmid, Thomas and Baadsvik, Emily Louise and Pruessmann, Klaas Paul},
  title = {Making RF coils MR ‐invisible by additive manufacturing using magnetically filled polymer},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70115}
}