EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers

C Velasco iD, C Castillo-Passi, N Chaher, D C Karampinos, P Irarrazaval iD, A Phinikaridou, R M Botnar, C Prieto

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30622 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von C Velasco und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK. Hauptthemen laut MEDLINE: Liver, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC, King's BHF Centre for Award Excellence RE, BHF Program Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a novel MR fingerprinting sequence using optimized motion‐compensated diffusion preparations for simultaneous T 1 , T 2 , and ADC quantification of liver tissue in a single breath‐held scan.

Methods

A radial spoiled gradient echo acquisition with magnetization preparation modules for T 1 , T 2, and ADC encoding is proposed. To compensate for the signal voids generated by the diffusion preparation, the combination of (1) a breath‐held scan, (2) peripheral pulse signal triggering, and (3) an optimized motion‐compensated diffusion‐preparation module is employed. Phantom experiments were performed to test the accuracy of the technique. The sequence was evaluated in 11 healthy subjects in comparison to conventional mapping techniques. Additional in vivo repeatability assessment experiments were performed.

Results

T 1 , T 2 , and ADC quantification showed good correlation (r 2 > 0.9 for all cases) with reference maps in phantoms and good agreement in vivo against clinical scans (bias not significantly different from zero). A peripheral pulse trigger delay of 200 ms was used to reduce cardiovascular motion artifacts. The repeatability tests prove a low interscan coefficient of variation and a high intraclass correlation coefficient of greater than 0.9 for all cases.

Conclusions

Simultaneous quantification of T 1 , T 2 , and ADC in liver tissue in a single MR fingerprinting scan of ˜16 s has been proposed, enabling a comprehensive evaluation of hepatic disease through co‐registered multiparametric imaging. Further studies are warranted to test this approach in patients with suspected diffuse liver disease to evaluate its potential for liver tissue characterization and tumor staging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverDiffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedHumansPhantoms, ImagingAdultReproducibility of ResultsMaleFemaleMotionHealthy VolunteersAlgorithmsArtifactsImage Interpretation, Computer-AssistedMiddle Aged

Stichwörter der Autor:innen

ADCMR fingerprintingMRFT1T2diffusion imaginglivermultiparametric imaging

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile.
  • Millenium Institute for Intelligent Healthcare Engineering, Santiago, Chile.
  • Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • School of Engineering, Electrical Engineering Department, Pontificia Universidad Católica de Chile, Santiago, Chile.

ORCID-Profile: C Velasco, P Irarrazaval

Förderung

  • EPSRC
  • King's BHF Centre for Award Excellence RE
  • BHF Program Grant
  • ANID FONDECYT
  • Wellcome Trust
  • Millenium Institute iHEALTH
  • Technical University of Munich -- Institute for Advanced Study
  • Wellcome EPSRC Centre for Medical Engineering

Zitieren

APA

Velasco, C., Castillo-Passi, C., Chaher, N., Karampinos, D. C., Irarrazaval, P., Phinikaridou, A., Botnar, R. M., & Prieto, C. (2025). Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30622

Vancouver

Velasco C, Castillo-Passi C, Chaher N, Karampinos DC, Irarrazaval P, Phinikaridou A, et al. Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30622

BibTeX
@article{Velasco2025,
  author = {Velasco, C and Castillo-Passi, C and Chaher, N and Karampinos, D C and Irarrazaval, P and Phinikaridou, A and Botnar, R M and Prieto, C},
  title = {Simultaneous liver T 1 , T 2 , and ADC MR fingerprinting using optimized motion‐compensated diffusion preparations: An initial validation on volunteers},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30622}
}
Kostenlos starten →