EUVIMEDEUVIMED entdecken
Open Access

Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss

Philip K Lee iD, Xuetong Zhou iD, Brian A Hargreaves

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30484 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Philip K Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Artifacts, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, GE Healthcare, NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Diffusion‐prepared imaging is a flexible alternative to conventional spin‐echo diffusion‐weighted EPI that allows selection of different imaging readouts and k‐space traversals, and permits control of image contrast or image artifacts. We investigate a new signal model and reconstruction for diffusion‐prepared imaging that addresses signal variations caused by motion‐sensitizing diffusion gradients.

Methods

A signal model, sampling theory, and reconstruction framework were developed assuming that motion‐induced phases and the measured signals are random variables. The reconstruction incorporates real‐valued amplitude weights estimated from low‐resolution images into a linear system. A diffusion‐prepared sequence was applied in phantom and in vivo acquisitions using different methods for managing phase errors from eddy currents or motion. This acquisition was performed with a high number of NEX and retrospectively undersampled to analyze errors in ADC estimation, and compared to spin‐echo diffusion‐weighted EPI, as well as conventional diffusion‐prepared methods. The B 1 sensitivity of the sequence was investigated using simulation and phantom experiments.

Results

Images reconstructed using the proposed method had similar image structures when compared to conventional spin‐echo diffusion‐weighted EPI, and demonstrated improved SNR efficiency compared to previous diffusion‐prepared approaches. ADC errors followed a trend consistent with the derived signal model, sampling theory, and expected B 1 sensitivity. The sampling requirement was shown to depend on the magnitude of motion‐induced phases, as well as phases from residual eddy currents.

Conclusion

Employing amplitude weights in the reconstruction of a diffusion‐prepared sequence can improve SNR efficiency at the cost of a greater minimum sampling time and increased sensitivity to B 1 inhomogeneity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingArtifactsBrainImage Processing, Computer-AssistedImage EnhancementPhantoms, ImagingHumansMotionAlgorithmsReproducibility of ResultsComputer SimulationSignal Processing, Computer-AssistedSensitivity and SpecificitySignal-To-Noise Ratio

Stichwörter der Autor:innen

diffusion MRIimage reconstructionlinear systems

Autor:innen und Institutionen

  • Radiology, Stanford University, Stanford, California, USA.
  • Bioengineering, Stanford University, Stanford, California, USA.
  • Electrical Engineering, Stanford University, Stanford, California, USA.

ORCID-Profile: Philip K Lee, Xuetong Zhou

Förderung

  • NCI NIH HHS
  • GE Healthcare
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Lee, P. K., Zhou, X., & Hargreaves, B. A. (2025). Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30484

Vancouver

Lee PK, Zhou X, Hargreaves BA. Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30484

BibTeX
@article{Lee2025,
  author = {Lee, Philip K and Zhou, Xuetong and Hargreaves, Brian A},
  title = {Diffusion‐prepared imaging with amplitude navigation for correction of motion‐induced signal loss},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30484}
}