EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

High‐resolution and high‐fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced‐ FOV multiplexed sensitivity encoding ( 3D ‐ rFOV ‐ MUSE )

Chenglang Yuan, Shihui Chen, Liyuan Liang, Xiaorui Xu, Hailin Xiong, Yi Li, Tianbaige Liu, Nan-Kuei Chen iD, Hing-Chiu Chang iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30455 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Chenglang Yuan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, China. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Diffusion Tensor Imaging, Cervical Cord, Spinal Cord. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Research Grant Council of Hong Kong.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a 3D isotropic high‐resolution and high‐fidelity cervical spinal cord DTI technique for addressing the current challenges existing in 2D cervical spinal cord DTI.

Methods

A 3D multi‐shot DWI acquisition and reconstruction technique was developed by combining 3D multiplexed sensitivity encoding (3D‐MUSE) with two reduced FOV techniques, termed 3D‐rFOV‐MUSE, to acquire 3D cervical spinal cord DTI data using a sagittal thin slab. A self‐referenced 2D ghost correction method and a 2D navigator‐based inter‐shot phase correction were integrated into the reconstruction framework to simultaneously eliminate Nyquist ghost and aliasing artifacts. Cardiac triggering was used during data acquisition to minimize the influence of cerebrospinal fluid pulsation. In vivo experiments were conducted on five healthy subjects at a 1.5 T MRI scanner for evaluating the feasibility of 3D cervical spinal cord DTI using 3D‐rFOV‐MUSE in terms of geometric fidelity, reconstruction performance, and SNR efficiency.

Results

A 3D‐rFOV‐MUSE can achieve high‐resolution cervical spinal cord DTI at 1.0 mm isotropic resolution. The integration of reduced FOV and multi‐shot acquisitions can improve the geometric fidelity of 3D cervical spinal cord DTI. Compared with routine 2D single‐shot diffusion‐weighed EPI (2D‐ss‐EPI), the proposed technique can mitigate through‐plane partial volume effect and enable multi‐planar data reformation for cervical spinal cord DTI, with effective reductions of distortions and improved signal‐to‐noise ratio.

Conclusion

We demonstrated the feasibility of high‐resolution and high‐fidelity 3D cervical spinal cord DTI at 1.0 mm isotropic resolution using 3D‐rFOV‐MUSE technique, which may potentially improve the quantitative assessment of cervical spinal cord DTI biomarkers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalDiffusion Tensor ImagingCervical CordSpinal CordImage Processing, Computer-AssistedHumansAlgorithmsAdultMaleSignal-To-Noise RatioFemaleArtifactsHealthy Volunteers

Stichwörter der Autor:innen

3D diffusion MRIMUSEcervical spinal corddiffusion tensor imaginghigh‐resolution DTImultiplexed sensitivity encodingreduced‐FOV

Autor:innen und Institutionen

  • Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, China.
  • Multi-Scale Medical Robotics Center, Hong Kong, China.
  • Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong, China.
  • Department of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.

ORCID-Profile: Nan-Kuei Chen, Hing-Chiu Chang

Förderung

  • Research Grant Council of Hong Kong

Zitieren

APA

Yuan, C., Chen, S., Liang, L., Xu, X., Xiong, H., Li, Y., Liu, T., Chen, N. K., & Chang, H. C. (2025). High‐resolution and high‐fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced‐ FOV multiplexed sensitivity encoding ( 3D ‐ rFOV ‐ MUSE ). Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30455

Vancouver

Yuan C, Chen S, Liang L, Xu X, Xiong H, Li Y, et al. High‐resolution and high‐fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced‐ FOV multiplexed sensitivity encoding ( 3D ‐ rFOV ‐ MUSE ). Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30455

BibTeX
@article{Yuan2025,
  author = {Yuan, Chenglang and Chen, Shihui and Liang, Liyuan and Xu, Xiaorui and Xiong, Hailin and Li, Yi and Liu, Tianbaige and Chen, Nan-Kuei and Chang, Hing-Chiu},
  title = {High‐resolution and high‐fidelity diffusion tensor imaging of cervical spinal cord using 3D reduced‐ FOV multiplexed sensitivity encoding ( 3D ‐ rFOV ‐ MUSE )},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30455}
}
Kostenlos starten →