Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Daniel Papp und 10 weiteren Autor:innen. Beteiligte Einrichtung: NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cervical Cord, Radio Waves. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Quebec BioImaging Network, Canada Foundation for Innovation, CIHR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Advancing the development of 7 T MRI for spinal cord imaging is crucial for the enhanced diagnosis and monitoring of various neurodegenerative diseases and traumas. However, a significant challenge at this field strength is the transmit field inhomogeneity. Such inhomogeneity is particularly problematic for imaging the small, deep anatomical structures of the cervical spinal cord, as it can cause uneven signal intensity and elevate the local specific absorption ratio, compromising image quality. This multisite study explores several RF shimming techniques in the cervical spinal cord.

Methods

Data were collected from 5 participants between two 7 T sites with a custom 8Tx/20Rx parallel transmission coil. We explored two radiofrequency (RF) shimming approaches from an MRI vendor and four from an open‐source toolbox, showcasing their ability to enhance transmit field and signal homogeneity along the cervical spinal cord.

Results

The circularly polarized (CP), coefficient of variation (CoV), and specific absorption rate (SAR) efficiency shim modes showed the highest B 1 + efficiency, and the vendor‐based “patient” and “volume” modes showed the lowest B 1 + efficiency. The coefficient of variation method produced the highest CSF/spinal cord contrast on T 2 *‐weighted scans (ratio of 1.27 ± 0.03), and the lowest variation of that contrast along the superior–inferior axis.

Conclusion

The study's findings highlight the potential of RF shimming to advance 7 T MRI's clinical utility for central nervous system imaging by enabling more homogenous and efficient spinal cord imaging. Additionally, the research incorporates a reproducible Jupyter Notebook, enhancing the study's transparency and facilitating peer verification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingCervical CordRadio WavesHumansMaleFemaleAdultImage Processing, Computer-AssistedSpinal CordAlgorithms

Stichwörter der Autor:innen

7TB1+radio‐frequencyshimmingspinal cord

Autor:innen und Institutionen

  • NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Quebec, Canada.
  • Centre for Functional and Metabolic Mapping, The University of Western Ontario, London, Ontario, Canada.
  • Department of Medical Biophysics, The University of Western Ontario, London, Ontario, Canada.
  • Centre de Recherche du CHU Sainte-Justine, Université de Montréal, Montreal, Quebec, Canada.
  • Siemens Healthcare Limited, Montreal, Quebec, Canada.
  • McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, Quebec, Canada.

ORCID-Profile: Daniel Papp, Kyle M Gilbert, Alexandre D'Astous, Mathieu Boudreau, Marcus J Couch, Pedram Yazdanbakhsh, Robert L Barry, Eva Alonso-Ortiz, Julien Cohen-Adad

Förderung

  • Quebec BioImaging Network
  • Canada Foundation for Innovation
  • CIHR
  • Fonds de Recherche du Québec - Santé
  • Natural Sciences and Engineering Research Council of Canada
  • NIBIB NIH HHS
  • NIH HHS
  • Canadian Institutes of Health Research

Zitieren

APA

Papp, D., Gilbert, K. M., Cereza, G., D'Astous, A., Lopez-Rios, N., Boudreau, M., Couch, M. J., Yazdanbakhsh, P., Barry, R. L., Alonso-Ortiz, E., & Cohen-Adad, J. (2024). RF shimming in the cervical spinal cord at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30225

Vancouver

Papp D, Gilbert KM, Cereza G, D'Astous A, Lopez-Rios N, Boudreau M, et al. RF shimming in the cervical spinal cord at 7 T. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30225

BibTeX
@article{Papp2024,
  author = {Papp, Daniel and Gilbert, Kyle M and Cereza, Gaspard and D'Astous, Alexandre and Lopez-Rios, Nibardo and Boudreau, Mathieu and Couch, Marcus J and Yazdanbakhsh, Pedram and Barry, Robert L and Alonso-Ortiz, Eva and Cohen-Adad, Julien},
  title = {RF shimming in the cervical spinal cord at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30225}
}
Kostenlos starten →