Low‐rank iterative infilling for zero echo‐time (ZTE) imaging
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30345 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Zimu Huo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Cambridge, UK. Hauptthemen laut MEDLINE: Algorithms, Monte Carlo Method, Signal-To-Noise Ratio, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Cambridge Biomedical Research Centre, Gates Cambridge Trust.
Abstract (Originalsprache)
Purpose
A new referenceless low‐rank reconstruction technique has been introduced to address the issue of missing samples within the Zero Echo Time (ZTE) dead‐time gap.
Methods
The proposed method reformulates the in‐filling of the missing samples as an inverse problem subject to low‐rank constraints. Its performance and robustness are evaluated through a comparative analysis that combines Monte Carlo computational simulations and data obtained from in vivo experiments.
Results
The proposed method is tested for dead‐time gaps ranging up to 4.5 Nyquist dwells, across signal‐to‐noise ratio levels of 5, 10, 15, and 20 dB. Consistently superior performance is observed across all cases compared to algebraic and parallel imaging methods. The speed for convergence decreases exponentially as the dead‐time gap expands.
Conclusion
The proposed method enables artifact‐free reconstruction up to dead‐time gap of 4 Nyquist dwells and thereby supports ZTE imaging up to an imaging bandwidth of kHz (assuming transmit and receive switching less than 30 s). It demonstrates superior performance compared to algebraic and parallel imaging methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Cambridge, UK.
- GE HealthCare, Amersham, UK.
- GE HealthCare, Munich, Germany.
- Department of Neuroimaging, Psychology and Neuroscience, King's College London, London, UK.
ORCID-Profile: Zimu Huo, José de Arcos, Joshua D Kaggie, Martin J Graves
Förderung
- NIHR Cambridge Biomedical Research Centre
- Gates Cambridge Trust
Zitieren
APA
Huo, Z., de Arcos, J., Wiesinger, F., Kaggie, J. D., & Graves, M. J. (2025). Low‐rank iterative infilling for zero echo‐time (ZTE) imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30345
Vancouver
Huo Z, de Arcos J, Wiesinger F, Kaggie JD, Graves MJ. Low‐rank iterative infilling for zero echo‐time (ZTE) imaging. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30345
BibTeX
@article{Huo2025,
author = {Huo, Zimu and de Arcos, José and Wiesinger, Florian and Kaggie, Joshua D and Graves, Martin J},
title = {Low‐rank iterative infilling for zero echo‐time (ZTE) imaging},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30345}
}
EUVIMED