Spiral 3DREAM sequence for fast whole‐brain B1 mapping
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30282 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Svenja Niesen und 3 weiteren Autor:innen. Beteiligte Einrichtung: MR Physics, German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Brain, Phantoms, Imaging, Algorithms. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
This work demonstrates a new variant of the 3DREAM sequence for whole‐brain mapping employing a three‐dimensional (3D) stack‐of‐spirals readout. The spiral readout reduces the echo train length after the STEAM preparation in order to overcome the significant blurring in STE* images due to the decreasing STE* signal with each excitation pulse.
Methods
The 3DREAM sequence rapidly acquires two contrasts to calculate whole‐brain flip angle maps. In the proposed spiral 3DREAM sequence, the Cartesian readout scheme is replaced by an accelerated 3D stack‐of‐spirals readout with a CAIPIRINHA sampling scheme. Phantom experiments were conducted to compare flip angle maps of the spiral 3DREAM sequence to a Cartesian 3DREAM sequence, an actual flip‐angle‐imaging (AFI) sequence, the dual‐angle method, and the Bloch–Siegert shift method. Afterwards, the results were validated in vivo acquiring flip angle maps from five subjects.
Results
Flip angle maps of the spiral 3DREAM sequences showed high agreement with the reference methods both in phantom and in vivo experiments. Blurring in STE* images and flip angle maps was reduced compared to the Cartesian 3DREAM sequence.
Conclusion
The spiral 3DREAM sequence utilizes a fast readout minimizing the echo train length of the imaging train. This reduces blurring in STE* images as well as the total acquisition time and increases the effective resolution of maps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- MR Physics, German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
- Department of Physics & Astronomy, University of Bonn, Bonn, Germany.
ORCID-Profile: Svenja Niesen, Marten Veldmann, Philipp Ehses, Tony Stöcker
Zitieren
APA
Niesen, S., Veldmann, M., Ehses, P., & Stöcker, T. (2025). Spiral 3DREAM sequence for fast whole‐brain B1 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30282
Vancouver
Niesen S, Veldmann M, Ehses P, Stöcker T. Spiral 3DREAM sequence for fast whole‐brain B1 mapping. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30282
BibTeX
@article{Niesen2025,
author = {Niesen, Svenja and Veldmann, Marten and Ehses, Philipp and Stöcker, Tony},
title = {Spiral 3DREAM sequence for fast whole‐brain B1 mapping},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30282}
}
EUVIMED