Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30420 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Xiaozhi Cao und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Stanford University, Stanford, California, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Brain, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NIMH NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
To provide a fast quantitative imaging approach for a 0.55T scanner, where signal‐to‐noise ratio is limited by the field strength and k‐space sampling speed is limited by a lower specification gradient system.
Methods
We adapted the three‐dimensional spiral projection imaging MR fingerprinting approach to 0.55T scanners, with additional features incorporated to improve the image quality of quantitative brain and musculoskeletal imaging, including (i) improved k‐space sampling efficiency, (ii) Cramér‐Rao lower bound optimized flip‐angle pattern for specified T 1 and T 2 at 0.55 T, (iii) gradient trajectory correction, (iv) attention‐based denoising, and (v) motion estimation and correction.
Results
The proposed MRF acquisition and reconstruction framework can provide high‐quality 1.2‐mm isotropic whole‐brain quantitative maps and 1‐mm isotropic knee quantitative maps, each acquired in 4.5 min. The proposed method was validated in both phantom and in vivo brain and knee studies.
Conclusion
By proposing novel methods and integrating advanced techniques, we achieved high‐isotropic‐resolution MRF on a 0.55T scanner, demonstrating enhanced efficiency, motion resilience, and quantitative accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Stanford University, Stanford, California, USA.
- Department of Electrical Engineering, Stanford University, Stanford, California, USA.
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
- Department of Radiation Oncology, City of Hope National Cancer Center, Los Angeles, California, USA.
ORCID-Profile: Xiaozhi Cao, Congyu Liao, Zheren Zhu, Zhitao Li, Rupsa Bhattacharjee, Zhixing Wang, Sharmila Majumdar, Yang Yang
Förderung
- NIBIB NIH HHS
- NIMH NIH HHS
- NIH HHS
- NICHD NIH HHS
- National Institutes of Health
Zitieren
APA
Cao, X., Liao, C., Zhu, Z., Li, Z., Bhattacharjee, R., Nishmura, M., Wang, Z., Wang, N., Zhou, Z., Chen, Q., Abraham, D., Majumdar, S., Villanueva-Meyer, J., Yang, Y., & Setsompop, K. (2025). Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30420
Vancouver
Cao X, Liao C, Zhu Z, Li Z, Bhattacharjee R, Nishmura M, et al. Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30420
BibTeX
@article{Cao2025,
author = {Cao, Xiaozhi and Liao, Congyu and Zhu, Zheren and Li, Zhitao and Bhattacharjee, Rupsa and Nishmura, Mark and Wang, Zhixing and Wang, Nan and Zhou, Zihan and Chen, Quan and Abraham, Daniel and Majumdar, Sharmila and Villanueva-Meyer, Javier and Yang, Yang and Setsompop, Kawin},
title = {Three‐dimensional high‐isotropic‐resolution MR fingerprinting optimized for 0. 55 T},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30420}
}