EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Run‐time motion and first‐order shim control by expanded servo navigation

Malte Riedel iD, Thomas Ulrich iD, Klaas P Pruessmann iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Malte Riedel und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland. Hauptthemen laut MEDLINE: Phantoms, Imaging, Brain, Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To provide a navigator‐based run‐time motion and first‐order field correction for three‐dimensional human brain imaging with high precision, minimal calibration and acquisition, and fast processing.

Methods

A complex‐valued linear perturbation model with feedback control is extended to estimate and correct for gradient shim fields using orbital navigators (2.3 ms). Two approaches for sensitizing the model to gradient fields are presented, one based on finite differences with three additional navigators, and another projection‐based approximation requiring no additional navigators. A mechanism for noise decorrelation of the matrix and the data is proposed and evaluated to reduce unwanted parameter biases.

Results

The rigid motion and first‐order field control achieves robust motion and gradient shim corrections improving image quality in a series of phantom and in vivo experiments with varying field conditions. In phantom scans, magnet drifts, forced gradient field perturbations and field distortions from shifts of a second bottle phantom are successfully corrected. Field estimates of the magnet drifts are in good agreement with concurrent field probe measurements. For in vivo scans, the proposed method mitigates field variations from torso motions while being robust to head motion. In vivo gradient field precisions were along with single‐digit micrometer and millidegree rigid precisions.

Conclusion

The navigator‐based method achieves accurate, high‐precision run‐time motion and field corrections with low sequence impact and calibration requirements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingBrainMagnetic Resonance ImagingAlgorithmsImaging, Three-DimensionalHumansMotionImage Processing, Computer-AssistedCalibrationArtifactsReproducibility of Results

Stichwörter der Autor:innen

feedback controlfield correctionhead motionlinear regressionmotion correctionorbital navigators

Autor:innen und Institutionen

  • Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland.

ORCID-Profile: Malte Riedel, Thomas Ulrich, Klaas P Pruessmann

Förderung

  • Horizon 2020 Framework Programme

Zitieren

APA

Riedel, M., Ulrich, T., & Pruessmann, K. P. (2025). Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30262

Vancouver

Riedel M, Ulrich T, Pruessmann KP. Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30262

BibTeX
@article{Riedel2025,
  author = {Riedel, Malte and Ulrich, Thomas and Pruessmann, Klaas P},
  title = {Run‐time motion and first‐order shim control by expanded servo navigation},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30262}
}