EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL ‐ MRA and super‐resolution convolutional neural network

Yuriko Suzuki iD, Ioannis Koktzoglou iD, Ziyu Li iD, Peter Jezzard iD, Thomas Okell

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30245 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Yuriko Suzuki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Neural Networks, Computer, Spin Labels, Imaging, Three-Dimensional. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Royal Academy of Engineering, NIHR Oxford Health Biomedical Research Centre, NIHR Oxford Biomedical Research Centre.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a novel framework to improve the visualization of distal arteries in arterial spin labeling (ASL) dynamic MRA.

Methods

The attenuation of ASL blood signal due to the repetitive application of excitation RF pulses was minimized by splitting the acquisition volume into multiple thin 2D (M2D) slices, thereby reducing the exposure of the arterial blood magnetization to RF pulses while it flows within the brain. To improve the degraded vessel visualization in the slice direction due to the limited minimum achievable 2D slice thickness, a super‐resolution (SR) convolutional neural network (CNN) was trained by using 3D time‐of‐flight (TOF)‐MRA images from a large public dataset. And then, we applied domain transfer from 3D TOF‐MRA to M2D ASL‐MRA, while avoiding acquiring a large number of ASL‐MRA data required for CNN training.

Results

Compared to the conventional 3D ASL‐MRA, far more distal arteries were visualized with higher signal intensity by using M2D ASL‐MRA. In general, however, the vessel visualization with a conventional interpolation was prone to be blurry and unclear due to the limited spatial resolution in the slice direction, particularly in small vessels. Application of CNN‐based SR transferred from 3D TOF‐MRA to M2D ASL‐MRA successfully addressed such a limitation and achieved clearer visualization of small vessels than conventional interpolation.

Conclusion

This study demonstrated that the proposed framework provides improved visualization of distal arteries in later dynamic phases, which will particularly benefit the application of this approach in patients with cerebrovascular disease who have slow blood flow.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyNeural Networks, ComputerSpin LabelsImaging, Three-DimensionalHumansMaleAdultFemaleBrainImage Processing, Computer-AssistedCerebrovascular CirculationCerebral ArteriesMiddle AgedAlgorithms

Stichwörter der Autor:innen

arterial spin labelingconvolutional neural networkdynamic MR angiographynon‐contrast MRAsuper‐resolution

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Department of Radiology, NorthShore University HealthSystem, Evanston, Illinois, USA.
  • Pritzker School of Medicine, University of Chicago, Chicago, Illinois, USA.

ORCID-Profile: Yuriko Suzuki, Ioannis Koktzoglou, Ziyu Li, Peter Jezzard

Förderung

  • Royal Academy of Engineering
  • NIHR Oxford Health Biomedical Research Centre
  • NIHR Oxford Biomedical Research Centre
  • Dunhill Medical Trust
  • Royal Society
  • Wellcome Trust

Zitieren

APA

Suzuki, Y., Koktzoglou, I., Li, Z., Jezzard, P., & Okell, T. (2024). Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL ‐ MRA and super‐resolution convolutional neural network. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30245

Vancouver

Suzuki Y, Koktzoglou I, Li Z, Jezzard P, Okell T. Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL ‐ MRA and super‐resolution convolutional neural network. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30245

BibTeX
@article{Suzuki2024,
  author = {Suzuki, Yuriko and Koktzoglou, Ioannis and Li, Ziyu and Jezzard, Peter and Okell, Thomas},
  title = {Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL ‐ MRA and super‐resolution convolutional neural network},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30245}
}
Kostenlos starten →