Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Qijia Shen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Angiography, Image Processing, Computer-Assisted, Arteries. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Oxford Biomedical Research Centre, Royal Academy of Engineering, Canada Research Chairs.
Abstract (Originalsprache)
Purpose
To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.
Methods
Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.
Results
The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.
Conclusion
Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
ORCID-Profile: Qijia Shen, Wenchuan Wu, Mark Chiew, Yang Ji, Joseph G Woods, Thomas W Okell
Förderung
- NIHR Oxford Biomedical Research Centre
- Royal Academy of Engineering
- Canada Research Chairs
- Wellcome Trust
Zitieren
APA
Shen, Q., Wu, W., Chiew, M., Ji, Y., Woods, J. G., & Okell, T. W. (2025). Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30407
Vancouver
Shen Q, Wu W, Chiew M, Ji Y, Woods JG, Okell TW. Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30407
BibTeX
@article{Shen2025,
author = {Shen, Qijia and Wu, Wenchuan and Chiew, Mark and Ji, Yang and Woods, Joseph G and Okell, Thomas W},
title = {Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30407}
}
EUVIMED