Ultra‐low‐field magnetization transfer imaging at 0.055T with low specific absorption rate

Shi Su, Yujiao Zhao, Ye Ding, Vick Lau, Linfang Xiao, Gilberto K K Leung, Gary K K Lau, Fan Huang iD, Vince Vardhanabhuti, Alex T L Leong, Ed X Wu iD

Magnetic Resonance in Medicine · 24.07.2024

DOI: 10.1002/mrm.30231 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.07.2024. Verfasst von Shi Su und 10 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Phantoms, Imaging, Brain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hong Kong Research Grant Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To demonstrate magnetization transfer (MT) effects with low specific absorption rate (SAR) on ultra‐low‐field (ULF) MRI.

Methods

MT imaging was implemented by using sinc‐modulated RF pulse train (SPT) modules to provide bilateral off‐resonance irradiation. They were incorporated into 3D gradient echo (GRE) and fast spin echo (FSE) protocols on a shielding‐free 0.055T head scanner. MT effects were first verified using phantoms. Brain MT imaging was conducted in both healthy subjects and patients.

Results

MT effects were clearly observed in phantoms using six SPT modules with total flip angle 3600° at central primary saturation bands of approximate offset ±786 Hz, even in the presence of large relative B 0 inhomogeneity. For brain, strong MT effects were observed in gray matter, white matter, and muscle in 3D GRE and FSE imaging using six and sixteen SPT modules with total flip angle 3600° and 9600°, respectively. Fat, cerebrospinal fluid, and blood exhibited relatively weak MT effects. MT preparation enhanced tissue contrasts in T2‐weighted and FLAIR‐like images, and improved brain lesion delineation. The estimated MT SAR was 0.0024 and 0.0008 W/kg for two protocols, respectively, which is far below the US Food and Drug Administration (FDA) limit of 3.0 W/kg.

Conclusion

Robust MT effects can be readily obtained at ULF with extremely low SAR, despite poor relative B 0 homogeneity in ppm. This unique advantage enables flexible MT pulse design and implementation on low‐cost ULF MRI platforms to achieve strong MT effects in brain and beyond, potentially augmenting their clinical utility in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingPhantoms, ImagingBrainHumansImage Processing, Computer-AssistedImaging, Three-DimensionalMaleAdultFemaleAlgorithmsGray MatterWhite Matter

Stichwörter der Autor:innen

MRIbrainmagnetization transferspecific absorption ratetissue contrastultra‐low‐field

Autor:innen und Institutionen

  • Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Hong Kong SAR, China.
  • Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong SAR, China.
  • Department of Surgery, The University of Hong Kong, Hong Kong SAR, China.
  • Department of Medicine, The University of Hong Kong, Hong Kong SAR, China.
  • Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong SAR, China.

ORCID-Profile: Fan Huang, Ed X Wu

Förderung

  • Hong Kong Research Grant Council

Zitieren

APA

Su, S., Zhao, Y., Ding, Y., Lau, V., Xiao, L., Leung, G. K. K., Lau, G. K. K., Huang, F., Vardhanabhuti, V., Leong, A. T. L., & Wu, E. X. (2024). Ultra‐low‐field magnetization transfer imaging at 0.055T with low specific absorption rate. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30231

Vancouver

Su S, Zhao Y, Ding Y, Lau V, Xiao L, Leung GKK, et al. Ultra‐low‐field magnetization transfer imaging at 0.055T with low specific absorption rate. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30231

BibTeX
@article{Su2024,
  author = {Su, Shi and Zhao, Yujiao and Ding, Ye and Lau, Vick and Xiao, Linfang and Leung, Gilberto K K and Lau, Gary K K and Huang, Fan and Vardhanabhuti, Vince and Leong, Alex T L and Wu, Ed X},
  title = {Ultra‐low‐field magnetization transfer imaging at 0.055T with low specific absorption rate},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30231}
}