Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Afis Ajala und 3 weiteren Autor:innen. Beteiligte Einrichtung: GE HealthCare, Technology and Innovation Center, Niskayuna, New York, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, Congressionally Directed Medical Research Programs.
Abstract (Originalsprache)
Purpose
MRI using 3D stack‐of‐spirals (SoS) readout on a high‐performance gradient system is subject to strong second‐order, spatially varying concomitant fields, which can lead to signal dropout and blurring artifacts that become more significant at locations farther from the gradient isocenter. A method for compensating for second‐order concomitant fields in 3D axial SoS image reconstruction is described.
Methods
We retrospectively correct for second‐order concomitant field–induced phase error in the 3D SoS data by slice‐dependent k‐space phase compensation based on the nominal spiral readout trajectories. The effectiveness of the method was demonstrated in phantom and healthy volunteer scans in which 3D pseudo‐continuous arterial spin labeling imaging was performed with SoS fast spin‐echo readout at 3 T.
Results
Substantial reduction in blurring was observed with the proposed method. In phantom scans, blurring was reduced by about 53% at 98 mm from the gradient isocenter. In the in vivo 3D pseudo‐continuous arterial spin labeling scans, differences of up to 10% were observed at 78 mm from the isocenter, especially around the white‐matter and gray‐matter interfaces, between the corrected and uncorrected proton density images, perfusion‐weighted images, and cerebral blood flow maps.
Conclusions
The described retrospective correction method provides a means to correct erroneous phase accruals due to second‐order concomitant fields in 3D axial stack‐of‐spirals imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- GE HealthCare, Technology and Innovation Center, Niskayuna, New York, USA.
ORCID-Profile: Afis Ajala
Förderung
- NINDS NIH HHS
- NIBIB NIH HHS
- Congressionally Directed Medical Research Programs
Zitieren
APA
Ajala, A., Abad, N., Foo, T. K. F., & Lee, S. K. (2024). Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30113
Vancouver
Ajala A, Abad N, Foo TKF, Lee SK. Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30113
BibTeX
@article{Ajala2024,
author = {Ajala, Afis and Abad, Nastaren and Foo, Thomas K F and Lee, Seung-Kyun},
title = {Retrospective correction of second‐order concomitant fields in 3D axial stack‐of‐spirals imaging on a high‐performance gradient system},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30113}
}
EUVIMED