EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T

Pedram Yazdanbakhsh iD, Marcus J Couch iD, Christian Sprang, Kyle M Gilbert iD, Sajjad Feizollah iD, Christine L Tardif iD, David A Rudko iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.70011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Pedram Yazdanbakhsh und 6 weiteren Autor:innen. Beteiligte Einrichtung: McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, Quebec, Canada. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Neuroimaging. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Azrieli Foundation, McGill Healthy Brains for Healthy Lives Initiative.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this work was to design and build a size‐adaptive pediatric RF head coil for 7 T neuroimaging. The coil can be safely applied for imaging children 4–9 years old.

Methods

The pediatric head coil incorporates eight, transmit dipole elements for operation in parallel transmit (pTx) mode. The receive architecture is comprised of a 32‐channel conformal, size‐adaptive receive array. Receive elements were arranged into five sections of a mechanically adjustable 3D printed head former, allowing adjustment of the receive array according to child head size. The transmit coil was carefully simulated to calculate specific absorption rate (SAR) and B 1 + efficiency. Coil performance was then evaluated with a pediatric head phantom at both the largest and smallest dimensions of the receive former. In vivo imaging was carried out in 3 pediatric subjects (aged 5, 6, and 9 years old) to acquire B 1 + field maps and anatomical MP2RAGE images.

Results

A comparison of simulated and experimental B 1 + performance in the pediatric head phantom was used to validate SAR models and to demonstrate that the coil was safe for pediatric imaging. The SNR performance in the pediatric phantom was improved by adjusting the position of the receive array to the smallest possible position. The in vivo B 1 + efficiency agreed with expectations, and the coil provided precise anatomical images of the brain.

Conclusions

The proposed size‐adaptive coil enables safe, high‐quality imaging of children at 7 T, with a range of ages and head sizes. Accurate SAR modeling enabled imaging using both combined circularly polarized and dynamic pTx modes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainNeuroimagingHumansChildPhantoms, ImagingChild, PreschoolEquipment DesignImage Processing, Computer-AssistedMaleSignal-To-Noise RatioRadio WavesHeadFemale

Stichwörter der Autor:innen

7 Tparallel Transmit (pTx)pediatricradiofrequency coilsultra high fieldvirtual observation points

Autor:innen und Institutionen

  • McConnell Brain Imaging Centre, Montreal Neurological Institute and Hospital, Montreal, Quebec, Canada.
  • Department of Neurology and Neurosurgery, McGill University, Montreal, Quebec, Canada.
  • Siemens Healthcare Limited, Montreal, Quebec, Canada.
  • Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada.
  • Centre for Functional and Metabolic Mapping, Western University, London, Ontario, Canada.

ORCID-Profile: Pedram Yazdanbakhsh, Marcus J Couch, Kyle M Gilbert, Sajjad Feizollah, Christine L Tardif, David A Rudko

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Azrieli Foundation
  • McGill Healthy Brains for Healthy Lives Initiative
  • Brain Canada Foundation
  • Canadian Foundation for Innovation
  • Fonds de Recherche du Québec - Nature et Technologies (FRQNT)
  • Fonds de Recherche du Québec - Santé
  • Fondation Brain Canada

Zitieren

APA

Yazdanbakhsh, P., Couch, M. J., Sprang, C., Gilbert, K. M., Feizollah, S., Tardif, C. L., & Rudko, D. A. (2025). A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70011

Vancouver

Yazdanbakhsh P, Couch MJ, Sprang C, Gilbert KM, Feizollah S, Tardif CL, et al. A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.70011

BibTeX
@article{Yazdanbakhsh2025,
  author = {Yazdanbakhsh, Pedram and Couch, Marcus J and Sprang, Christian and Gilbert, Kyle M and Feizollah, Sajjad and Tardif, Christine L and Rudko, David A},
  title = {A size‐adaptive RF coil for MRI of the pediatric human brain at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.70011}
}
Kostenlos starten →