EUVIMEDFaigh amach EUVIMED
CrossrefCárta eolais

A Prospective Comparative Study of High‐Yield Plateletpheresis Using Haemonetics MCS +, Trima Accel, and Spectra Optia Devices in a Resource‐Constrained Setting

Eiman Hussein, Azza A. Aboul Enein

Journal of Clinical Apheresis · 2025-10 · 40 (5)

DOI: 10.1002/jca.70054 ↗
AchoimreSonraí leabharliosta

Achoimre

ABSTRACT In a resource‐constrained setting, maximizing plateletpheresis efficiency is critical. We believe leveraging advanced apheresis device software to enhance platelet yield, reduce consumables, and shorten procedure times offers significant advantages. This study compared Haemonetics, Trima, and Optia apheresis devices, analyzing donor and machine parameters. It also assessed how high‐yield collections and recent software updates on Trima and Haemonetics devices impact donor safety. The goal was to find the best practices for optimizing both donor safety and platelet collection. Analyzing 900 procedures (300 per device), Trima and Optia yielded significantly more platelets (9 × 10 11 ) in less time compared to Haemonetics (5.7 × 10 11 ) ( p < 0.05). Trima collected10–12 × 10 11 platelets from significantly more donors with lower pre‐donation counts than Optia ( p < 0.05). Optia led to the fewest adverse events (0.7%). Donor weight was significantly higher for yields > 9 × 10 11 on Optia and Trima ( p < 0.05). Haemonetics' 3.6–3.8 × 10 11 yield group had significantly lower session time, donor weight, and presession platelet counts ( p < 0.05). Software updates (200 sessions/device) significantly boosted Trima's yields to 14.8 × 10 11 while reducing adverse events (1% vs. 2.3% pre‐update). Haemonetics also saw improved yields and fewer adverse events (1% vs. 4.3%), though its overall yield remained lower (6.3 × 10 11 , p < 0.05). Both maintained safe post‐procedure platelet counts (> 130 000/μL). However, Trima's predicted yields for very high collections (> 12 × 10 11 ) significantly differed from lab‐determined yields. Trima and Optia provide better platelet collection efficiency than Haemonetics. Software updates improved both Trima and Haemonetics' performance and safety; however, Trima's high‐yield predictions need refining. Optimal settings, updated software, and careful donor selection are essential for maximizing platelet yield and donor safety in resource‐limited areas.

Eolas a oireann do do chuid oibre.

Ó thús saor in aisce agus taighde litríochta pearsanta go dtí an Research Suite iomlán.

Féach ar na taraifí →

An bhfuil gach téacs iomlán ó fhoilsitheoirí san áireamh?

Ní hea. Is ábhair éagsúla iad tagairtí bibleagrafaíocha, achoimrí agus lánthéacsanna. Braitheann fáil an lánthéacs ar an bhfoinse, Open Access agus ar na ceadúnais atá agat cheana. Ní chuireann taraif EUVIMED cearta breise foilsitheora ina n-ionad.

Féach ar na taraifí →