Patient‐Specific Strategy for Coronary Alignment in TAVI With Evolut FX+
Catheterization and Cardiovascular Interventions · 2026-03 · 107 (4) · 1112-1119
DOI: 10.1002/ccd.70446 ↗Kurz gefasst
Video/Audio in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 30.12.2025. Verfasst von Michele Galasso und 12 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine and Surgery, Milano-Bicocca University, Milan, Italy. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve, Aortic Valve Stenosis. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
Coronary access after transcatheter aortic valve implantation (TAVI) is an increasingly relevant issue, particularly in patients who may require future coronary interventions or redo‐TAVI procedures. Although commissural alignment is routinely achieved in surgical valve replacement, it remains challenging during TAVI because of anatomical variability and reliance on two‐dimensional fluoroscopic guidance. Moreover, optimal commissural alignment does not necessarily ensure adequate coronary alignment, as the spatial relationship between native commissures and coronary ostia varies substantially among individuals. This work describes a patient‐specific, CT‐ and fluoroscopy‐guided strategy to optimize coronary alignment during TAVI using the Evolut FX+ platform. The proposed approach integrates systematic pre‐procedural CT analysis of coronary ostial position, intercoronary angle, and valve geometry with the identification of a customized fluoroscopic implantation view, termed the Coronary Customized Projection. This projection is applied during valve deployment to guide valve orientation and enable mono‐coronary or bi‐coronary alignment according to individual anatomy. The strategy enhances procedural control and aims to preserve coronary access without increasing procedural complexity. Prospective studies are warranted to evaluate its impact on coronary reaccess and long‐term clinical outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Medicine and Surgery, Milano-Bicocca University, Milan, Italy.
- Valve Center, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
- University of Milan, Milan, Italy.
- Department of Cardiovascular and Thoracic Sciences, Catholic University of the Sacred Heart, Rome, Italy.
- Medtronic Italia S.p.A., Milano, Italia.
ORCID-Profile: Michele Galasso, Emmanuel Villa
Zitieren
APA
Galasso, M., Cattaneo, G., Casamassima, F., Bellamoli, M., Bettari, L., Buono, A., Zito, A., Troise, G., Villa, E., Messina, A., Arneri, A., Maggi, A., & Maffeo, D. (2026). Patient‐Specific Strategy for Coronary Alignment in TAVI With Evolut FX+. Catheterization and Cardiovascular Interventions, 107(4), 1112-1119. https://doi.org/10.1002/ccd.70446
Vancouver
Galasso M, Cattaneo G, Casamassima F, Bellamoli M, Bettari L, Buono A, et al. Patient‐Specific Strategy for Coronary Alignment in TAVI With Evolut FX+. Catheterization and Cardiovascular Interventions. 2026;107(4):1112-1119. doi:10.1002/ccd.70446
BibTeX
@article{Galasso2026,
author = {Galasso, Michele and Cattaneo, Greta and Casamassima, Fabio and Bellamoli, Michele and Bettari, Luca and Buono, Andrea and Zito, Andrea and Troise, Giovanni and Villa, Emmanuel and Messina, Antonio and Arneri, Andrea and Maggi, Antonio and Maffeo, Diego},
title = {Patient‐Specific Strategy for Coronary Alignment in TAVI With Evolut FX+},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
volume = {107},
number = {4},
pages = {1112--1119},
doi = {10.1002/ccd.70446}
}
EUVIMED