EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY-NC-ND 4.0

Left Ventricular Outflow Tract Geometry as a Predictor of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Using the Evolut Series

Mahmoud Abdelshafy iD, Angela McInerney, Ahmed Elmeanawy, Paolo Alberto Del Sole iD, Max Wagener, Hatem Helal, Mahmoud Abozaid, Ashraf Alamir, Tamer Fouad, Alsayed Almarghany, Briain MacNeill, Osama Soliman iD und 2 weitere

Catheterization and Cardiovascular Interventions · 2026

DOI: 10.1002/ccd.70474 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2026. Verfasst von Mahmoud Abdelshafy und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Al-Azhar University, Cairo, Egypt. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Transcatheter Aortic Valve Replacement, Cardiac Pacing, Artificial, Heart Valve Prosthesis. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Predicting the need for permanent pacemaker implantation (PPM) after transcatheter aortic valve implantation (TAVI) is crucial for procedural planning and patient counseling.

Aims

To evaluate whether left ventricular outflow tract (LVOT) morphology, specifically a tapered configuration, predicts conduction disturbances requiring PPM after TAVI using the Evolut self‐expanding valve.

Methods

This retrospective multicenter study included patients undergoing TAVI with the self‐expanding Evolut series. Pre‐TAVI MSCT analysis included LVOT shape, membranous septum (MSep) length, and landing‐zone calcification. Implantation depth (ID) was measured on final aortography.

Results

A total of 189 patients were included (age, 79.2 ± 6.8 years, 46% female, EuroSCORE II, 3.1 [1.9, 5.6]). Seventeen patients (9%) required PPM at 30 days. Patients with a tapered LVOT had a threefold higher PPM rate compared with those with a non‐tapered configuration (21% vs. 7%, p = 0.015). PPM was significantly associated with tapered LVOT (OR: 4.2, p = 0.041), pre‐existing right bundle branch block (RBBB) (OR: 12.4, p = 0.001), and deep valve implantation with a short MSep (OR: 16.4, p < 0.001).

Conclusion

Tapered LVOT configuration, pre‐existing RBBB, and deep implantation in the context of a short MSep are independent predictors of PPM following TAVI with the Evolut TAVI platform. Integrating LVOT configuration and MSep length into preprocedural planning may improve patient selection and prediction of PPM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialTranscatheter Aortic Valve ReplacementCardiac Pacing, ArtificialHeart Valve ProsthesisAortic Valve StenosisAortic ValveArrhythmias, CardiacHumansFemaleRetrospective StudiesAged, 80 and overTreatment OutcomeRisk FactorsProsthesis DesignTime FactorsAgedMalePredictive Value of TestsRisk AssessmentMultidetector Computed Tomography

Stichwörter der Autor:innen

LVOTTAVIcomputed tomographyconduction disturbancepacemaker implantation

Autor:innen und Institutionen

  • Department of Cardiology, Al-Azhar University, Cairo, Egypt.
  • Department of Cardiology, Galway University Hospitals and University of Galway, Galway, Ireland.
  • Department of Cardiology, Nasr City Health Insurance Hospital, Cairo, Egypt.
  • Royal College of Surgeons in Ireland (RCSI), University of Medicine and Health Sciences, Dublin, Ireland.
  • Precision Cardiovascular Medicine & Innovation Institute (PCMI), Cardiovascular Research Institute (CVRI), Mater Private Network, Dublin, Ireland.
  • Cardiology Unit, Internal Medicine Department, Sohar Hospital, Sohar, Oman.

ORCID-Profile: Mahmoud Abdelshafy, Paolo Alberto Del Sole, Osama Soliman, Mohammad Abdelghani

Zitieren

APA

Abdelshafy, M., McInerney, A., Elmeanawy, A., Sole, P. A. D., Wagener, M., Helal, H., Abozaid, M., Alamir, A., Fouad, T., Almarghany, A., MacNeill, B., Soliman, O., Mylotte, D., & Abdelghani, M. (2026). Left Ventricular Outflow Tract Geometry as a Predictor of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Using the Evolut Series. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70474

Vancouver

Abdelshafy M, McInerney A, Elmeanawy A, Sole PAD, Wagener M, Helal H, et al. Left Ventricular Outflow Tract Geometry as a Predictor of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Using the Evolut Series. Catheterization and Cardiovascular Interventions. 2026. doi:10.1002/ccd.70474

BibTeX
@article{Abdelshafy2026,
  author = {Abdelshafy, Mahmoud and McInerney, Angela and Elmeanawy, Ahmed and Sole, Paolo Alberto Del and Wagener, Max and Helal, Hatem and Abozaid, Mahmoud and Alamir, Ashraf and Fouad, Tamer and Almarghany, Alsayed and MacNeill, Briain and Soliman, Osama and Mylotte, Darren and Abdelghani, Mohammad},
  title = {Left Ventricular Outflow Tract Geometry as a Predictor of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Using the Evolut Series},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2026},
  doi = {10.1002/ccd.70474}
}
Kostenlos starten →