EUVIMEDEUVIMED entdecken
Vergleichsstudie

Interaction Between Guiding‐Extension Catheter and Drug‐Eluting Stents: Always Safe or Sometimes Harmful?

Salvatore Colangelo iD, Riccardo Mangione iD, Mario Iannaccone, Francesco Colombo, Giacomo Giovanni Boccuzzi

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.70035 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Salvatore Colangelo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Intervention, San Giovanni Bosco Hospital, Torino, Italy. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Percutaneous Coronary Intervention, Cardiac Catheters, Coronary Artery Disease. Die Arbeit nennt 6 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Guiding‐extension catheters (GECs) provide enhanced support to guiding catheter (GC) during complex percutaneous coronary intervention (PCI). However, by reducing the inner cross‐sectional diameter, they can create high friction between the GEC and the drug‐eluting stents (DES), potentially causing abrasion and damage to the abluminal struts.

Aim

This study aims to compare the performances of the Amphilimus Cre8 EVO polymer‐free DES with all the other surface‐coated DES. The abluminal grooves of this polymer‐free DES, which contain the drug and avoid any risk of its abrasion and detachment (abluminal reservoir technology), may offer a protective effect during stent advancement within the GEC.

Methods

Between January 2019 and April 2024, 218 patients who underwent complex PCI procedures with the insertion of a DES and the use of GEC were enrolled in the study. They were divided into Group A (39 patients) received the Amphilimus polymer‐free DES, while Group B (179 patients) received other types of DES. To evaluate the efficacy and safety of the DES used, a device‐oriented composite endpoint (DoCE) was assessed at one year of follow‐up. This composite endpoint included Cardiovascular Death, Target Vessel Myocardial Infarction, and Clinically and Physiologically indicated Target Lesion Revascularization.

Results

At the one‐year follow‐up, the primary endpoint demonstrated a statistically significant difference between the two groups. Event‐free survival from DoCE was 97.4% in Group A compared to 85.5% in Group B (Log rank = 0.027). Additionally, there was a significant difference in mean stent length between the groups: Group A had a longer mean stent length of 52.4 ± 38.6 mm, while Group B had a mean length of 40.4 ± 22.6 mm, with a p ‐value of 0.01. All other clinical and procedural variables were similar between the two groups.

Conclusion

Our findings suggest that the polymer‐free DES tested in this study appears to be the most effective option when using GECs, as it may help prevent negative interactions between the inner surface of GEC and the abluminal struts of the DES.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drug-Eluting StentsPercutaneous Coronary InterventionCardiac CathetersCoronary Artery DiseaseCardiac CatheterizationHumansMaleFemaleAgedMiddle AgedTime FactorsProsthesis DesignTreatment OutcomeRisk FactorsRetrospective StudiesRisk Assessment

Autor:innen und Institutionen

  • Cardiovascular Intervention, San Giovanni Bosco Hospital, Torino, Italy.

ORCID-Profile: Salvatore Colangelo, Riccardo Mangione

Zitieren

APA

Colangelo, S., Mangione, R., Iannaccone, M., Colombo, F., & Boccuzzi, G. G. (2025). Interaction Between Guiding‐Extension Catheter and Drug‐Eluting Stents: Always Safe or Sometimes Harmful?. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70035

Vancouver

Colangelo S, Mangione R, Iannaccone M, Colombo F, Boccuzzi GG. Interaction Between Guiding‐Extension Catheter and Drug‐Eluting Stents: Always Safe or Sometimes Harmful?. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70035

BibTeX
@article{Colangelo2025,
  author = {Colangelo, Salvatore and Mangione, Riccardo and Iannaccone, Mario and Colombo, Francesco and Boccuzzi, Giacomo Giovanni},
  title = {Interaction Between Guiding‐Extension Catheter and Drug‐Eluting Stents: Always Safe or Sometimes Harmful?},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.70035}
}
Kostenlos starten →