Early Vascular Response of a Biodegradable Polymer‐Coated Sirolimus‐Eluting Stent in Patients With ST‐Segment Elevation Myocardial Infarction—The OCIMI Study
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.70046 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Atul Abhyankar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Shri B D Mehta Mahavir Heart Institute, Surat, India. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Sirolimus, ST Elevation Myocardial Infarction, Percutaneous Coronary Intervention. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Few studies have addressed the early healing pattern of ultrathin strut drug‐eluting stents implanted specifically for the treatment of acute myocardial infarction. AIMS This study employed optical coherence tomography (OCT) to assess neointimal coverage and vascular healing following implantation of ultrathin biodegradable polymer‐coated sirolimus‐eluting stents (SES) in patients with ST‐segment elevation myocardial infarction (STEMI).
Methods
The OCIMI study was a prospective, single‐center investigation of 23 STEMI patients treated with Supraflex Cruz SES (Sahajanand Medical Technologies Ltd., Surat, India) during primary PCI between September 2019 and June 2020. All patients underwent OCT imaging at 3‐month follow‐up, and images were analyzed at an independent core laboratory by analysts blinded to clinical and procedural data.
Results
At the 3‐month follow‐up, no clinical events were reported. The analyzed stent length was 28.4 ± 12.0 mm, with a stent diameter of 2.70 ± 0.46 mm and a reference lumen diameter of 2.46 ± 0.44 mm. OCT demonstrated nearly complete stent strut coverage (99.94%), with uncovered struts observed in 0.06 ± 0.16% of total struts per stent. Incomplete stent apposition was present in 0.14 ± 0.37% of struts. The mean neointimal hyperplasia (NIH) area and thickness were 0.81 ± 0.40 mm 2 and 110 ± 40 µm, respectively, with a mean NIH unevenness score of 1.74 ± 0.19.
Conclusion
Primary PCI performed with Supraflex Cruz SES demonstrated excellent early vascular healing at the 3‐month OCT follow‐up. The extremely low incidence of uncovered struts may have implications for abbreviated dual antiplatelet therapy in high‐bleeding risk STEMI patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shri B D Mehta Mahavir Heart Institute, Surat, India.
- Stanford University, Stanford, California, USA.
- Sahajanand Medical Technologies Limited, Surat, India.
ORCID-Profile: Atul Abhyankar, Yamunesh Patel
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Abhyankar, A., Patel, B., Jain, A., Patel, V., Patel, Y., Saito, K., Yoshida, A., Honda, Y., & Sudhir, K. (2025). Early Vascular Response of a Biodegradable Polymer‐Coated Sirolimus‐Eluting Stent in Patients With ST‐Segment Elevation Myocardial Infarction—The OCIMI Study. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.70046
Vancouver
Abhyankar A, Patel B, Jain A, Patel V, Patel Y, Saito K, et al. Early Vascular Response of a Biodegradable Polymer‐Coated Sirolimus‐Eluting Stent in Patients With ST‐Segment Elevation Myocardial Infarction—The OCIMI Study. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.70046
BibTeX
@article{Abhyankar2025,
author = {Abhyankar, Atul and Patel, Bhargav and Jain, Ankit and Patel, Vikas and Patel, Yamunesh and Saito, Kan and Yoshida, Akihiro and Honda, Yasuhiro and Sudhir, Krishnankutty},
title = {Early Vascular Response of a Biodegradable Polymer‐Coated Sirolimus‐Eluting Stent in Patients With ST‐Segment Elevation Myocardial Infarction—The OCIMI Study},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.70046}
}
EUVIMED