EUVIMEDOdkrijte EUVIMED
CrossrefInformacijska kartica

Comparison of p‐Tm:YAG, TFL and Ho:YAG's in vitro ablation rates on synthetic and human stones

Frédéric Panthier, Alba Sierra, Etienne Xavier Keller, Marie Chicaud, Eugenio Ventimiglia, Jia‐Lun Kwok, Vincent De Coninck, Mariela Corrales, Michel Daudon, Cyril Gorny, Steeve Doizi, Laurent Berthe, Daron Smith, Olivier Traxer

BJUI Compass · 2025-08 · 6 (8)

DOI: 10.1002/bco2.70067 ↗
PovzetekBibliografski podatki

Povzetek

Abstract Objective To compare in vitro the ablation rates of p‐Tm:YAG, TFL and Ho:YAG against synthetic and human stones. Material and Methods p‐Tm:YAG, TFL and Low‐Power (LP) Ho:YAG were compared using 270 μm core‐diameter laser fibres (CDF); experiments with 200 μm(p‐Tm:YAG) and 150 μm‐CDF (TFL) were also included. A continuous laser emission was applied through a spiral trajectory for 20 seconds with the laser fibre tip in contact with synthetic hard (HSP) and soft stone phantoms (SSP) submerged in saline. “Dusting” settings for p‐Tm:YAG(0,6 J‐20 Hz‐Flex Long Pulse), TFL(0,5 J‐30 Hz‐Short Pulse) and Ho:YAG(0,5 J‐30 Hz‐Long Pulse) and “Fragmentation” settings for p‐Tm:YAG(1 J‐15 Hz‐Captive), TFL(1 J‐15 Hz‐Short Pulse) and Ho:YAG(1 J‐15 Hz‐Long Pulse) were analysed. Then, experiments for human calcium oxalate monohydrate (COM), uric acid (UA) and cystine (CYS) stones were performed with single laser pulses at 0.6 J, 0.8 J and 1.0 J for p‐Tm:YAG (Captive Fragmenting mode), TFL (Short Pulse) and Ho:YAG (Long Pulse). Synthetic and human stone samples were dried before three‐dimensional scanning to measure ablation rates (ARs) and ablation volume per pulse (AVP). Results For synthetic stones with 270 μm‐CDF, the p‐Tm:YAG and TFL presented similar ARs, except in Fragmentation against HSP (95,1 ± 13,6vs67 ± 14 p = 0,02, respectively). Both p‐Tm:YAG and TFL achieved higher ARs than Ho:YAG in all settings. p‐Tm:YAG‐200 μm‐CDF and TFL‐150 μm‐CDF presented similar ARs, except in Fragmentation against HSP(78,4 ± 8vs42,5 ± 2,6 mm 3 /min,p = 0,0002). Both p‐Tm:YAG‐200 μm‐CDF and TFL‐150 μm‐CDF presented at least 50% higher ARs than 270 μm‐Ho:YAG. For human stones with COM, TFL exhibited higher AVP compared to p‐Tm:YAG and Ho:YAG across all pulse energies (258,2 ± 213vs81,7 ± 31,9vs41,5 ± 25,4 μm 3 p = 0,01, respectively). Against UA, Ho:YAG demonstrated higher AVP compared to TFL and p‐Tm:YAG (355,2 ± 161vs99,8 ± 76,7vs292,9 ± 203,1 μm 3 p = 0,0005, respectively). For CYS, Ho:YAG presented higher AVP but without significance (99,8 ± 76,7 vs 49,3 ± 36,3 vs 38,8 ± 12,2 μm 3 , p = 0,09). Conclusion p‐Tm:YAG and TFL achieved higher ARs than LP‐Ho:YAG against synthetic stones in vitro. For human stones, TFL achieved the highest AVP against COM while LP‐Ho:YAG delivered higher AVPs against UA and CYS, for which TFL performed worst.

Znanje, ki ustreza vašemu delu.

Od brezplačnega začetka in osebnega iskanja literature do celotnega paketa Research Suite.

Ogled tarif →

Ali so vključena vsa polna besedila založnikov?

Ne. Bibliografski zapisi, povzetki in celotna besedila so različne vsebine. Ali je celotno besedilo na voljo, je odvisno od vira, odprtega dostopa in vaših obstoječih licenc. Paket EUVIMED ne nadomešča dodatnih pravic založnikov.

Ogled tarif →