Background
Mandibular angle fractures present a unique biomechanical challenge due to high distraction forces exerted by the masticatory muscles. Open reduction and internal fixation (ORIF) strategies continue to evolve to optimize stability while reducing complications.
Objective
To compare the intraoperative efficiency, biomechanical stability, and postoperative complication rates of three-dimensional (3D) miniplates versus conventional 2.0 mm miniplates for managing isolated mandibular angle fractures.
Methods
A prospective, randomized clinical trial was performed on 60 adult patients presenting with recent, isolated mandibular angle fractures. Patients were allocated into two equal cohorts: Group A (n=30) underwent fixation utilizing a single 1.0 mm thick titanium 3D miniplate via Champy's ideal osteosynthesis line, while Group B (n=30) underwent fixation using two conventional 2.0 mm titanium miniplates via a standard transbuccal approach. Primary outcome variables measured included operative time, primary hardware stability, post-surgical malocclusion, and hardware failure rates.
Results
The mean operative time was significantly shorter in Group A (46.5+- 5.1) minutes) compared to Group B (64.8+-7.2) minutes; (p < 0.001). Postoperative occlusal discrepancy was observed in 3.3% (n=1) of patients in Group A compared to 16.7% (n=5) in Group B (p = 0.03). Hardware failure, presenting as minor plate bending or splaying, occurred exclusively in Group B (6.7%, n=2). Both groups achieved satisfactory long-term bone healing, but Group A exhibited reduced early postoperative morbidity.
Conclusion
3D miniplates offer superior geometric stability against torsional forces at the mandibular angle compared to conventional miniplates. The 3D system dramatically reduces intraoperative time and minimizes immediate post-surgical malocclusion, rendering it a highly reliable clinical choice for mandibular angle trauma reconstruction.
Zitieren
APA
Youssef, D. M. M., & Ibrahim, D. Y. H. A. (2026). Efficacy of Three-Dimensional Miniplates Versus Conventional Miniplates in The Management of Mandibular Angle Fractures: A Comparative Clinical Study. Adolescência e Saúde, 3487-3489. https://doi.org/10.67440/ahj.vi.2945
Vancouver
Youssef DMM, Ibrahim DYHA. Efficacy of Three-Dimensional Miniplates Versus Conventional Miniplates in The Management of Mandibular Angle Fractures: A Comparative Clinical Study. Adolescência e Saúde. 2026:3487-3489. doi:10.67440/ahj.vi.2945
BibTeX
@article{Youssef2026,
author = {Youssef, Dr. Modar Mustafa and Ibrahim, Dr. Yassin Hassan Abdelgader},
title = {Efficacy of Three-Dimensional Miniplates Versus Conventional Miniplates in The Management of Mandibular Angle Fractures: A Comparative Clinical Study},
journal = {Adolescência e Saúde},
year = {2026},
pages = {3487--3489},
doi = {10.67440/ahj.vi.2945}
}
EUVIMED