EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Calibration variance outperforms predictive uncertainty in activity-only allostatic load

Jaba Tkemaladze

Longevity Horizon · 09.05.2026 · 2 (5)

DOI: 10.65649/eqwt3660 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Longevity Horizon, online erschienen am 09.05.2026. Verfasst von Jaba Tkemaladze. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Allostatic load (AL) indices suffer from extreme methodological heterogeneity (I² = 94.24%) and non‑specificity across clinical populations . Recent empirical work on “digital phenotyping” of AL demonstrates associations between traditional AL indices and wearable‑assessed physiological responses (energy expenditure, heart rate, detrended fluctuation analysis) , motivating the development of principled, dynamic AL measures grounded in predictive processing theories .

Methods

We introduce v4 of the Ze‑AL formalism: (i) substitution of predictive uncertainty σ_E(t) with calibration variance σ_calib² — the expected prediction variance from a stress‑free baseline; (ii) multivariate Mahalanobis distance across physiological channels. (Variational free energy analysis is provided in Supplementary Materials.) All variants were tested against simulated ground‑truth burden, a nonlinear outcome surrogate, and a truly independent behavioral target (theoretical ceiling r = 0.30). An antagonistic‑channel condition tested whether Mahalanobis distance requires coherent channel coupling. Key robustness tests: (a) multi‑seed analysis (10 seeds); (b) colored noise (1/f spectrum, β = 1.0); (c) unsupervised contamination (no information about which baseline samples are contaminated) with robust covariance estimation (DDCMV) .

Results

Under clean calibration, all GP‑based methods achieved r_burden ≈ 0.95–0.96. Under 10% calibration contamination, only σ_calib retained practical utility (r_burden = 0.893 [95% CI 0.872–0.911]), while the moving‑average baseline reversed sign catastrophically (r = −0.842). Under 30% contamination, σ_calib still dominated (r_burden = 0.938). Under colored noise (1/f), σ_calib maintained r_burden > 0.87. Under unsupervised contamination, σ_calib with robust covariance estimation (DDCMV) achieved r_burden = 0.824 (95% CI 0.781–0.862). Antagonistic‑channel coupling did not degrade Mahalanobis performance (r_burden = 0.951). Multi‑seed analysis confirmed robustness (σ_calib: SD = 0.003).

Conclusion

Under realistic calibration contamination — unavoidable in field studies — univariate σ_calib normalisation is the most robust estimator. For unsupervised settings, robust covariance estimation (DDCMV) restores performance. v4 σ_calib is recommended as the primary deployable measure for real‑world allostatic load research.

Zitieren

APA

Tkemaladze, J. (2026). Calibration variance outperforms predictive uncertainty in activity-only allostatic load. Longevity Horizon, 2(5). https://doi.org/10.65649/eqwt3660

Vancouver

Tkemaladze J. Calibration variance outperforms predictive uncertainty in activity-only allostatic load. Longevity Horizon. 2026;2(5). doi:10.65649/eqwt3660

BibTeX
@article{Tkemaladze2026,
  author = {Tkemaladze, Jaba},
  title = {Calibration variance outperforms predictive uncertainty in activity-only allostatic load},
  journal = {Longevity Horizon},
  year = {2026},
  volume = {2},
  number = {5},
  doi = {10.65649/eqwt3660}
}
Kostenlos starten →