EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Finite element analysis of a novel modular support system for lumbar reconstruction following vertebral column resection

Andhika Yudistira, Respati Suryanto Dradjat, Edi Mustamsir, Mochamad Agus Choiron, Yuyun Yueniwati, Hidayat Sujuti, I Ketut Suyasa

World Journal of Orthopedics · 2026-11-18 · 17 (11)

DOI: 10.5312/wjo.124459 ↗
AbstractBibliografische Angaben

Abstract

BACKGROUND Posterior vertebral column resection (VCR) is an effective procedure for treating severe rigid spinal deformities. However, this technique carries a high risk of nerve injury associated with the surgical approach. Conventional titanium mesh cages are widely used for anterior column support but have several reported disadvantages, including implant dislocation and subsidence, which may contribute to implant failure. AIM To evaluate a VCR modular support system (VCR-MSS) as an anterior-posterior construct for the Indonesian lumbar population. METHODS A 2-stage finite element analysis (FEA) framework was used. First, an ASTM F1717-21 polyethylene block model was used to validate the FEA methodology against mechanical testing of a posterior fixation prototype. Subsequently, the validated FEA framework was used to evaluate a conventional mesh cage construct and the proposed VCR-MSS under standardized loading in ASTM-based models and physiological loading in vertebra-based lumbar models. RESULTS In the preliminary stage, the ASTM-based model supported validation of the FEA methodology against mechanical testing of the posterior fixation prototype. In the main analysis, the VCR-MSS construct demonstrated greater structural stability than the conventional mesh cage construct. Total deformation was reduced from 6.0443 mm to 0.8435 mm under ASTM-based compressive loading and from 0.1100 mm to 0.0687 mm under vertebra-based flexion loading. In addition, posterior rod stress under ASTM-based compression was reduced from 429.09 MPa to 90.55 MPa, indicating improved load sharing with the VCR-MSS construct. CONCLUSION The VCR-MSS construct demonstrated greater stability and reduced posterior rod mechanical burden through integrated load sharing, suggesting its potential as a reconstruction option following lumbar VCR.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →