EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2 * Image

Zikuan Chen, Vince Calhoun

Magnetic Resonance Insights · 2013

DOI: 10.4137/mri.s11920 ↗
AbstractBibliografische Angaben

Abstract

Background and Purpose Recent research has shown that a T2 * image (either magnitude or phase) is not identical to the internal spatial distribution of a magnetic susceptibility (χ) source. In this paper, we examine the reasons behind these differences by looking into the insights of T2 * -weighted magnetic resonance imaging (T2 * MRI) and provide numerical characterizations of the source/image mismatches by numerical simulations. Methods For numerical simulations of T2 * MRI, we predefine a 3D χ source and calculate the complex-valued T2 * image by intravoxel dephasing in presence and absence of diffusion. We propose an empirical α-power model to describe the overall source/image transformation. For a Gaussian-shaped χ source, we numerically characterize the source/image morphological mismatch in terms of spatial correlation and FWHM (full width at half maximum). Results In theory, we show that the χ-induced fieldmap is morphologically different from the χ source due to dipole effect, and the T2 * magnitude image is related to the fieldmap by a quadratic transformation in the small phase angle regime, which imposes an additional morphological change. The numerical simulations with a Gaussian-shaped χ source show that a T2 * magnitude image may suffer an overall source/image morphological shrinkage of 20% to 25% and that the T2 * phase image is almost identical to the fieldmap thus maintaining a morphological mismatch from the χ source due to dipole effect. Conclusion The morphological mismatch between a bulk χ source and its T2 * image is caused by the 3D convolution during tissue magnetization (dipole effect), the nonlinearity of the T2 * magnitude and phase calculation, and the spin diffusion effect. In the small phase angle regime, the T2 * magnitude exhibits an overall morphological shrinkage, and the T2 * phase image suffers a dipole effect but maintains the χ-induced fieldmap morphology.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →