Accuracy and clinical outcomes of pancreatic EUS-guided fine-needle biopsy in a consecutive series of 852 specimens
Endoscopic Ultrasound · 2022-07 · 11 (4) · 306-318
DOI: 10.4103/eus-d-21-00180 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopic Ultrasound, 2022-07. Verfasst von Mikkel Marschall Thomsen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Odense University Hospital; Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Ode…. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background and Objectives: Pancreatic EUS-guided fine needle biopsy (EUS-FNB) is increasingly used. Accuracy of EUS-FNB, particularly for benign diseases, utility of additional EUS-FNB if malignancy is suspected but initial diagnosis is inconclusive, and complication rate are not fully elucidated. We evaluated operating characteristics of EUS-FNB overall and for different diagnostic categories, value of additional EUS-FNB if malignancy is suspected but initial diagnosis is inconclusive, and frequency and type of complications.
Methods
A retrospective tertiary single-center study including 852 consecutive pancreatic SharkCore EUS-FNBs from 723 patients between 2015 and 2020. EUS-FNB diagnoses were applied according to Papanicolaou Society's system and each category was further subcategorized.
Results
Sufficient tissue cylinders for a histologic diagnosis were obtained in 93.4% (796/852). Accuracy was overall, for malignant, and benign entities 85.6% (confidence interval [CI]: 83.2%–87.9%), 88.3% (CI: 85.9%–90.4%), and 94% (CI: 92.2%–95.5%). Sensitivity and accuracy of EUS-FNB for autoimmune pancreatitis (AIP) ( n = 15) was 83.3% (CI: 58.6%–96.4%) and 99.2% (CI: 98.3%–99.7%). Of patients in whom malignancy was suspected but initial EUS-FNB diagnosis was inconclusive, 7.3% (53/723) underwent one or two additional EUS-FNBs, and in 54.7% (29/53) of these, a malignant diagnosis was established. The frequency of hospitalization following EUS-FNB was 4.7%, with 0.2% ( n = 2) incidents needing active intervention.
Conclusions
We found a high accuracy of pancreatic EUS-FNB across all diagnostic categories including rare entities, such as AIP. In patients with a clinical suspicion of malignancy, additional EUS-FNB resulted in a conclusive diagnosis in more than half of cases. Complications necessitate hospitalization in almost 5%, but the majority are self-limiting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology, Odense University Hospital; Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark.
- Department of Surgery, Upper GI and HPB Section, Odense University Hospital, Odense, Denmark.
- Department of Pathology, Odense University Hospital, Odense, Denmark.
- Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark; Department of Surgery, Upper GI and HPB Section, Odense University Hospital; Odense Pancreas Center (OPAC), Odense University…
- Department of Pathology, Odense University Hospital; Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark; Odense Pancreas Center (OPAC), Odense University Hospital, Odense, Denmar…
Zitieren
APA
Thomsen, M. M., Larsen, M. H., Di Caterino, T., Hedegaard Jensen, G., Mortensen, M. B., & Detlefsen, S. (2022). Accuracy and clinical outcomes of pancreatic EUS-guided fine-needle biopsy in a consecutive series of 852 specimens. Endoscopic Ultrasound, 11(4), 306-318. https://doi.org/10.4103/eus-d-21-00180
Vancouver
Thomsen MM, Larsen MH, Di Caterino T, Hedegaard Jensen G, Mortensen MB, Detlefsen S. Accuracy and clinical outcomes of pancreatic EUS-guided fine-needle biopsy in a consecutive series of 852 specimens. Endoscopic Ultrasound. 2022;11(4):306-318. doi:10.4103/eus-d-21-00180
BibTeX
@article{Thomsen2022,
author = {Thomsen, Mikkel Marschall and Larsen, Michael Hareskov and Di Caterino, Tina and Hedegaard Jensen, Gitte and Mortensen, Michael Bau and Detlefsen, Sönke},
title = {Accuracy and clinical outcomes of pancreatic EUS-guided fine-needle biopsy in a consecutive series of 852 specimens},
journal = {Endoscopic Ultrasound},
year = {2022},
volume = {11},
number = {4},
pages = {306--318},
doi = {10.4103/eus-d-21-00180}
}
EUVIMED