EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Evaluation and Comparison of Marginal Adaptation of Computer-aided Design and Manufacturing Monolithic Polyether Ether Ketone and Zirconia Crown after 6 Months of Simulated Clinical Use: An In vitro Pilot Study

Ramanpreet Kaur, Veena Jain, Dheeraj Kumar Koli, Aditi Nanda, Tapas Chandra Nag

Contemporary Clinical Dentistry · 2026-04 · 17 (2) · 97-102

DOI: 10.4103/ccd.ccd_644_25 ↗
AbstractBibliografische Angaben

Abstract

Abstract Context (Background): Marginal adaptation is a key determinant of the longevity and clinical success of fixed dental prostheses. Polyether ether ketone (PEEK), a high-performance polymer, has recently gained interest as an alternative to zirconia due to its favorable mechanical, esthetic, and biological properties. Aims: To evaluate and compare the marginal adaptation of computer-aided design and manufacturing (CAD-CAM) monolithic PEEK and zirconia crowns cemented on natural teeth after simulating 6 months of clinical service. Settings and Design: An in vitro comparative pilot study was conducted using 28 extracted mandibular molars divided into two groups ( n = 14): Group I (PEEK) and Group II (Zirconia). Materials and Methods: Crowns were fabricated using CAD-CAM and cemented with self-adhesive resin cement. All specimens underwent thermocycling (120,000 cycles) and cyclic loading, followed by silver nitrate dye penetration. Sectioned specimens were examined under a scanning electron microscope (SEM) to assess vertical and horizontal marginal gaps. Statistical Analysis Used: Data were analyzed using SPSS v20. Normality was tested with the Shapiro–Wilk test, showing nonnormal distribution. The Mann–Whitney U test compared groups, with significance set at P < 0.05 (α = 0.05). Results: Group I (PEEK) showed mean horizontal and vertical marginal gaps of 35.09 ± 16.79 μm and 32.71 ± 17.85 μm, respectively, while Group II (Zirconia) showed 25.88 ± 23.45 μm and 26.53 ± 8.69 μm. Differences were statistically insignificant ( P > 0.05). Conclusions: Both PEEK and zirconia exhibited clinically acceptable marginal adaptation after simulated clinical aging. PEEK demonstrates comparable marginal accuracy to zirconia and can serve as a viable restorative alternative.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →