EUVIMEDEUVIMED entdecken
Crossref

X-Ray Inspection of LTCC Devices: Theory and Practice

Krzysztof Zaraska, Janina Gaudyn, Adam Bienńkowski, Marek Dohnalik, Andrzej Czerwiński, Mariusz Płuska, Monika Machnik, Katarzyna Wójcik

Journal of Microelectronics and Electronic Packaging · 01.04.2011 · 8 (2) · 49-57

DOI: 10.4071/imaps.289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Microelectronics and Electronic Packaging, erschienen am 01.04.2011. Verfasst von Krzysztof Zaraska und 7 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The appeal of the LTCC (low temperature cofired ceramic) process lies in the possibility of creating multilayer (3D) structures, integrating conductor paths between passive elements, such as inductors, resistors, and resonance cavities. Unfortunately, the very nature of a cofired device makes postfiring optical inspection of buried elements impossible, as the ceramic material is opaque to visible light. This limitation, however, does not exist at x-ray wavelengths. The aim of this paper is to provide a practical overview of the application of high resolution x-ray imaging for nondestructive inspection and fault detection in multilayer LTCC structures. First, we present a simplified mathematical description of x-ray absorption inside an LTCC structure and demonstrate that due to the physical properties of the substrate (glass/Al2O3 ceramic), the conductor material (silver), and the cavity fill (air), a high contrast image of the investigated structure can be obtained. Next, we show the application of a commercial off the shelf industrial x-ray system for imaging various faults in LTCC structures, such as via voids (caused by inadequate filling of a via hole with conductor material), microcracks, paste creep (during lamination, excess via conductor leaks out of the via hole and in between the tape layers, shorting the via to an adjacent circuit), interruptions in conductor paths, and alignment errors. We also demonstrate the application of computed tomography to verify 3D geometry of buried resonance cavities and detect tape delaminations. Finally, we discuss the limitations of the method, related to structure thickness (number of layers), material composition, imaging geometry, and equipment characteristics, such as detector resolution and spatial noise.

Zitieren

APA

Zaraska, K., Gaudyn, J., Bienńkowski, A., Dohnalik, M., Czerwiński, A., Płuska, M., Machnik, M., & Wójcik, K. (2011). X-Ray Inspection of LTCC Devices: Theory and Practice. Journal of Microelectronics and Electronic Packaging, 8(2), 49-57. https://doi.org/10.4071/imaps.289

Vancouver

Zaraska K, Gaudyn J, Bienńkowski A, Dohnalik M, Czerwiński A, Płuska M, et al. X-Ray Inspection of LTCC Devices: Theory and Practice. Journal of Microelectronics and Electronic Packaging. 2011;8(2):49-57. doi:10.4071/imaps.289

BibTeX
@article{Zaraska2011,
  author = {Zaraska, Krzysztof and Gaudyn, Janina and Bienńkowski, Adam and Dohnalik, Marek and Czerwiński, Andrzej and Płuska, Mariusz and Machnik, Monika and Wójcik, Katarzyna},
  title = {X-Ray Inspection of LTCC Devices: Theory and Practice},
  journal = {Journal of Microelectronics and Electronic Packaging},
  year = {2011},
  volume = {8},
  number = {2},
  pages = {49--57},
  doi = {10.4071/imaps.289}
}
Kostenlos starten →