EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 3.0

Supervised deep learning-based synthetic computed tomography from kilovoltage cone-beam computed tomography images for adaptive radiation therapy in head and neck cancer

Chirasak Khamfongkhruea, Tipaporn Prakarnpilas, Sangutid Thongsawad, Aphisara Deeharing, Thananya Chanpanya, Thunpisit Mundee, Pattarakan Suwanbut, Kampheang Nimjaroen

Radiation Oncology Journal · 30.09.2024 · 42 (3) · 181-191

DOI: 10.3857/roj.2023.00584 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Oncology Journal, erschienen am 30.09.2024. Verfasst von Chirasak Khamfongkhruea und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Program, Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To generate and investigate a supervised deep learning algorithm for creating synthetic computed tomography (sCT) images from kilovoltage cone-beam computed tomography (kV-CBCT) images for adaptive radiation therapy (ART) in head and neck cancer (HNC).Materials and methods: This study generated the supervised U-Net deep learning model using 3,491 image pairs from planning computed tomography (pCT) and kV-CBCT datasets obtained from 40 HNC patients. The dataset was split into 80% for training and 20% for testing. The evaluation of the sCT images compared to pCT images focused on three aspects: Hounsfield units accuracy, assessed using mean absolute error (MAE) and root mean square error (RMSE); image quality, evaluated using the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) between sCT and pCT images; and dosimetric accuracy, encompassing 3D gamma passing rates for dose distribution and percentage dose difference.

Results

MAE, RMSE, PSNR, and SSIM showed improvements from their initial values of 53.15 ± 40.09, 153.99 ± 79.78, 47.91 ± 4.98 dB, and 0.97 ± 0.02 to 41.47 ± 30.59, 130.39 ± 78.06, 49.93 ± 6.00 dB, and 0.98 ± 0.02, respectively. Regarding dose evaluation, 3D gamma passing rates for dose distribution within sCT images under 2%/2 mm, 3%/2 mm, and 3%/3 mm criteria, yielded passing rates of 92.1% ± 3.8%, 93.8% ± 3.0%, and 96.9% ± 2.0%, respectively. The sCT images exhibited minor variations in the percentage dose distribution of the investigated target and structure volumes. However, it is worth noting that the sCT images exhibited anatomical variations when compared to the pCT images.

Conclusion

These findings highlight the potential of the supervised U-Net deep learningmodel in generating kV-CBCT-based sCT images for ART in patients with HNC.

Schlagwörter

Stichwörter der Autor:innen

Adaptive radiation therapyCone-beam computed tomographyDeep learningHead and neck cancerSupervised U-NetSynthetic CT

Autor:innen und Institutionen

  • Medical Physics Program, Princess Srisavangavadhana College of Medicine, Chulabhorn Royal Academy, Bangkok, Thailand.
  • Department of Radiation Oncology, Chulabhorn Hospital, Chulabhorn Royal Academy, Bangkok, Thailand.

Zitieren

APA

Khamfongkhruea, C., Prakarnpilas, T., Thongsawad, S., Deeharing, A., Chanpanya, T., Mundee, T., Suwanbut, P., & Nimjaroen, K. (2024). Supervised deep learning-based synthetic computed tomography from kilovoltage cone-beam computed tomography images for adaptive radiation therapy in head and neck cancer. Radiation Oncology Journal, 42(3), 181-191. https://doi.org/10.3857/roj.2023.00584

Vancouver

Khamfongkhruea C, Prakarnpilas T, Thongsawad S, Deeharing A, Chanpanya T, Mundee T, et al. Supervised deep learning-based synthetic computed tomography from kilovoltage cone-beam computed tomography images for adaptive radiation therapy in head and neck cancer. Radiation Oncology Journal. 2024;42(3):181-191. doi:10.3857/roj.2023.00584

BibTeX
@article{Khamfongkhruea2024,
  author = {Khamfongkhruea, Chirasak and Prakarnpilas, Tipaporn and Thongsawad, Sangutid and Deeharing, Aphisara and Chanpanya, Thananya and Mundee, Thunpisit and Suwanbut, Pattarakan and Nimjaroen, Kampheang},
  title = {Supervised deep learning-based synthetic computed tomography from kilovoltage cone-beam computed tomography images for adaptive radiation therapy in head and neck cancer},
  journal = {Radiation Oncology Journal},
  year = {2024},
  volume = {42},
  number = {3},
  pages = {181--191},
  doi = {10.3857/roj.2023.00584}
}
Kostenlos starten →