Effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prosthesis
Journal of Dental Research, Dental Clinics, Dental Prospects · 2020-11-11 · 14 (4) · 218-222
DOI: 10.34172/joddd.2020.039 ↗Abstract
Background. Designing a high strength all-ceramic fixed partial denture with favorable esthetics can be challenging for clinicians; this study aimed to evaluate the effect of connector size and design on the fracture resistance of monolithic zirconia fixed dental prostheses. Methods. Two groups of twenty 3-unit monolithic zirconia (Sirona inCoris TZI, Sirona Dental Systems GmbH) bridges, extending from the mandibular first premolar to the first molar with different connector sizes (9 mm2 and 12 mm2 ), were divided into two subgroups with different connector designs (round and sharp). The specimens were subjected to the three-point bending test to obtain the fracture-bearing load. The results were reported using descriptive statistics (mean ± standard deviation). Mann-Whitney U test was used to compare the fracture load in two types of designs for each connector size and two connector size types for each connector design. The significance level was considered at P