SMART MAT: Fibre Optic Innovation for Bedside Monitoring and Validation of Continuous Vital Signs

Jace L A Ng, Ahmad Azeem Bin Noordin, Clare W M Chan, Jael Chew, Clarissa W Q Lim, Nikhil T Sanghavi, Omar Arif Bin Mohamed Murat, Hao Wen Tan, Lyn S Yeo, Esther M Y Yow, Meredith T Yeung iD

Sensors · 2025

DOI: 10.3390/s25175321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jace L A Ng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Health and Social Sciences Cluster, Singapore Institute of Technology, Singapore 828608, Singapore. Hauptthemen laut MEDLINE: Vital Signs, Fiber Optic Technology. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Masstron Pte Ltd..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vital sign monitoring is fundamental to patient care. Although traditional intermittent systems are flawed, barriers to implementing continuous monitoring systems remain. The SMART MAT is a novel continuous monitoring device that detects vital signs remotely via fibre optic technology. The study aims to validate the SMART MAT and its paired devices against gold/clinical standard measurements for measuring heart rate (HR), respiratory rate (RR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and oxygen saturation (SpO2). Healthy adults aged 21 to 80 were recruited for this cross-sectional study. Participants rested supine on a standardised mattress with the SMART MAT below. Vital signs were recorded over three five-minute intervals. Statistical analysis included descriptive statistics, two-way ANOVA, Mean Absolute Percentage Error (MAPE), and Bland–Altman plots. Among 321 participants recruited, HR and most RR measurements saw non-statistically significant differences (p > 0.05). Statistically significant differences were observed for SBP, SpO2, and most DBP measurements (p < 0.05). Only SBP measurements exceeded the acceptable limits of differences. Effect sizes were small to negligible (n2 < 0.04) and MAPE values were

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vital SignsFiber Optic TechnologyHumansAdultMiddle AgedMaleFemaleMonitoring, PhysiologicAgedHeart RateBlood PressureRespiratory RateCross-Sectional StudiesAged, 80 and overYoung AdultOxygen SaturationPoint-of-Care Systems

Stichwörter der Autor:innen

continuous monitoringfibre optic technologyhealthcare technologypatient careremote monitoringvital sign monitoring

Autor:innen und Institutionen

  • Health and Social Sciences Cluster, Singapore Institute of Technology, Singapore 828608, Singapore.

ORCID-Profile: Meredith T Yeung

Förderung

  • Masstron Pte Ltd.

Zitieren

APA

Ng, J. L. A., Noordin, A. A. B., Chan, C. W. M., Chew, J., Lim, C. W. Q., Sanghavi, N. T., Murat, O. A. B. M., Tan, H. W., Yeo, L. S., Yow, E. M. Y., & Yeung, M. T. (2025). SMART MAT: Fibre Optic Innovation for Bedside Monitoring and Validation of Continuous Vital Signs. Sensors. https://doi.org/10.3390/s25175321

Vancouver

Ng JLA, Noordin AAB, Chan CWM, Chew J, Lim CWQ, Sanghavi NT, et al. SMART MAT: Fibre Optic Innovation for Bedside Monitoring and Validation of Continuous Vital Signs. Sensors. 2025. doi:10.3390/s25175321

BibTeX
@article{Ng2025,
  author = {Ng, Jace L A and Noordin, Ahmad Azeem Bin and Chan, Clare W M and Chew, Jael and Lim, Clarissa W Q and Sanghavi, Nikhil T and Murat, Omar Arif Bin Mohamed and Tan, Hao Wen and Yeo, Lyn S and Yow, Esther M Y and Yeung, Meredith T},
  title = {SMART MAT: Fibre Optic Innovation for Bedside Monitoring and Validation of Continuous Vital Signs},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25175321}
}
Kostenlos starten →